A Thermal Comfort Levels Investigation of a Naturally Ventilated and Air-Conditioned Office

被引:0
|
作者
Daghigh, R. [1 ]
Adam, N. M. [1 ]
Sopian, K. [2 ]
Zaharim, A. [2 ]
Sahari, B. B. [3 ]
机构
[1] Univ Putra Malaysia, Dept Mech & Mfg Engn, Serdang, Malaysia
[2] Univ Kebangsaan Malaysia, Solar Energy ResInst, Bangi 43600, Malaysia
[3] Univ Putra Malaysia, Inst Adv Technol, Serdang 43400, Malaysia
关键词
Thermal Comfort; Neutral Temperature; Naturally Ventilated; Mechanically Ventilation; Objective Study; Subjective Approach; PMV;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of this study is to investigate thermal comfort levels of a naturally ventilated and air-conditioner office. Field experiments conducted in an office room in Universiti Putra Malaysia (UPM) used survey questionnaires and physical measurements. When air conditioner was working, it was found that the office was slightly cool based on ISO 7730, but result of survey revealed that staff found condition to be cool. In naturally ventilated condition objective result showed that this office is uncomfortable but subjective study revealed that staffs found condition to be comfortable. Results of over 40 survey responses to thermal comfort questions in study room at UPM are presented. Responses from those staff suggest a wider acceptable temperature range for occupants.
引用
收藏
页码:189 / +
页数:3
相关论文
共 50 条
  • [1] Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms
    Fabozzi, Michael
    Dama, Alessandro
    [J]. INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 851 - 859
  • [2] A TALE OF 2 POPULATIONS - THERMAL COMFORT IN AIR-CONDITIONED AND NATURALLY VENTILATED OFFICES IN THAILAND
    BUSCH, JF
    [J]. ENERGY AND BUILDINGS, 1992, 18 (3-4) : 235 - 249
  • [3] THERMAL COMFORT IN THE HUMID TROPICS - FIELD EXPERIMENTS IN AIR-CONDITIONED AND NATURALLY VENTILATED BUILDINGS IN SINGAPORE
    DEDEAR, RJ
    LEOW, KG
    FOO, SC
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1991, 34 (04) : 259 - 265
  • [4] Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China
    Yang, Wei
    Zhang, Guoqiang
    [J]. INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2008, 52 (05) : 385 - 398
  • [5] Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China
    Wei Yang
    Guoqiang Zhang
    [J]. International Journal of Biometeorology, 2008, 52 : 385 - 398
  • [6] Thermal comfort and IAQ characteristics of naturally/mechanically ventilated and air-conditioned bedrooms in a hot and humid climate
    Sekhar, S. C.
    Goh, S. E.
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (10) : 1905 - 1916
  • [7] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    [J]. INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [8] Occupant comfort in naturally ventilated and mixed-mode spaces within air-conditioned offices
    Drake, Scott
    de Dear, Richard
    Alessi, Angela
    Deuble, Max
    [J]. ARCHITECTURAL SCIENCE REVIEW, 2010, 53 (03) : 297 - 306
  • [9] Thermal preference and comfort assessment in air-conditioned and naturally -ventilated university classrooms under hot and humid conditions in Brazil
    Buonocore, Carolina
    De Vecchi, Renata
    Scalco, Veridiana
    Lamberts, Roberto
    [J]. ENERGY AND BUILDINGS, 2020, 211
  • [10] Thermal comfort study of naturally ventilated office
    Laska, Marta
    [J]. 9TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING (EKO-DOK 2017), 2017, 17