Screening for indoor air quality of air-conditioned off ices

被引:12
|
作者
Wong, L. T. [1 ]
Mui, K. W. [1 ]
Hui, P. S. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
screening test; indoor air pollutants; IAQ index; air-conditioned offices;
D O I
10.1177/1420326X07082159
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It would be costly to sample all toxic air pollutants to which an entire community is exposed. In Hong Kong, a voluntary Indoor Air Quality (IAQ) certification scheme for IAQ assessment in workplaces proposes the measurement of the levels of 12 parameters: carbon dioxide, carbon monoxide, respirable suspended particulates, nitrogen dioxide, ozone, formaldehyde, total volatile organic compounds, radon, airborne bacteria count, temperature, relative humidity and air velocity. This study investigates the feasibility of a screening process for presumptive detection of unrecognised IAQ problems in an indoor environment. From the full IAQ assessment results of 422 air-conditioned offices in Hong Kong, three of nine listed common air pollutants are selected as "representative" pollutants for an overall "satisfactory IAQ". In particular, an "IAQ index" using the average fractional dose corresponding to given exposure limits of the representative pollutants as a simple screening test for asymptomatic IAQ problems in air-conditioned offices is proposed. The index was evaluated in terms of test sensitivity, specificity and predictive value. Such a screening test would be a useful tool for policyrnakers, building owners and professionals to identify offices with probable IAQ problems. Making better decisions regarding resources for an IAQ surveillance programme could help to ensure a healthy and safe workplace.
引用
收藏
页码:438 / 443
页数:6
相关论文
共 50 条
  • [1] Evaluation on screening strategies for indoor air quality assessments in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2009, 30 (03): : 203 - 212
  • [2] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [3] Screening Strategies of an Indoor Air Quality Express Assessment Protocol (EAP) for Air-conditioned Offices
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2009, 18 (01) : 77 - 82
  • [4] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [5] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [6] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    [J]. INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [7] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [8] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    [J]. BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [9] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    [J]. BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [10] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    [J]. INDOOR AIR, 2003, 13 (04) : 315 - 331