Screening for indoor air quality of air-conditioned off ices

被引:12
|
作者
Wong, L. T. [1 ]
Mui, K. W. [1 ]
Hui, P. S. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
screening test; indoor air pollutants; IAQ index; air-conditioned offices;
D O I
10.1177/1420326X07082159
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It would be costly to sample all toxic air pollutants to which an entire community is exposed. In Hong Kong, a voluntary Indoor Air Quality (IAQ) certification scheme for IAQ assessment in workplaces proposes the measurement of the levels of 12 parameters: carbon dioxide, carbon monoxide, respirable suspended particulates, nitrogen dioxide, ozone, formaldehyde, total volatile organic compounds, radon, airborne bacteria count, temperature, relative humidity and air velocity. This study investigates the feasibility of a screening process for presumptive detection of unrecognised IAQ problems in an indoor environment. From the full IAQ assessment results of 422 air-conditioned offices in Hong Kong, three of nine listed common air pollutants are selected as "representative" pollutants for an overall "satisfactory IAQ". In particular, an "IAQ index" using the average fractional dose corresponding to given exposure limits of the representative pollutants as a simple screening test for asymptomatic IAQ problems in air-conditioned offices is proposed. The index was evaluated in terms of test sensitivity, specificity and predictive value. Such a screening test would be a useful tool for policyrnakers, building owners and professionals to identify offices with probable IAQ problems. Making better decisions regarding resources for an IAQ surveillance programme could help to ensure a healthy and safe workplace.
引用
收藏
页码:438 / 443
页数:6
相关论文
共 50 条
  • [31] DISINFECTING AIR-CONDITIONED AIR
    不详
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +
  • [32] Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
    Wong, NH
    Huang, B
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (09) : 1115 - 1123
  • [33] Effects of Partition on Thermal Comfort, Indoor Air Quality, Energy Consumption, and Perception in Air-Conditioned Buildings
    Aryal, Pradip
    Leephakpreeda, Thananchai
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (05):
  • [34] Outdoor pollutants effect on air quality of air-conditioned room
    Zheng, Jianxiang
    Zhou, Lei
    [J]. ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 1379 - 1384
  • [35] Thermal Conditions and Perceived Air Quality in an Air-conditioned Auditorium
    Polednik, Bernard
    Guz, Lukasz
    Skwarczynski, Mariusz
    Dudzinska, Marzenna R.
    [J]. THERMOPHYSICS 2016: 21ST INTERNATIONAL MEETING, 2016, 1752
  • [36] Air quality appraisal in air-conditioned spaces: Numerical analysis
    Kameel, R
    Khalil, EE
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 287 - 294
  • [37] Air Quality Assessment for the Microenvironment in Air-conditioned Passenger Trains
    Cai Wei
    Wang Danjun
    Yu Xubo
    [J]. EBM 2010: INTERNATIONAL CONFERENCE ON ENGINEERING AND BUSINESS MANAGEMENT, VOLS 1-8, 2010, : 3601 - 3604
  • [38] Cross-city comparison of indoor air temperatures in air-conditioned spaces
    Kim, H.
    Chun, C.
    Kwok, A.
    Ota, A.
    Tamura, A.
    [J]. INDOOR AIR, 2011, 21 (04) : 311 - 318
  • [39] Ionization of air in an air-conditioned building
    Behounek, F
    Kletschka, J
    [J]. NATURE, 1938, 142 : 956 - 956