Measurement and evaluation of indoor air quality in naturally ventilated residential buildings

被引:41
|
作者
Yin, Haiguo [1 ,2 ]
Liu, Chunxue [1 ]
Zhang, Leiming [1 ]
Li, Angui [1 ]
Ma, Zhenjun [2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, 13 Yanta Rd, Xian 710055, Shaanxi, Peoples R China
[2] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW, Australia
关键词
Residential buildings; Natural ventilation; Indoor air quality; Pollutants; Air infiltration rate; Field measurement; INITIAL EMITTABLE CONCENTRATION; VOLATILE ORGANIC-COMPOUNDS; FORMALDEHYDE CONCENTRATIONS; OUTDOOR AIR; POLLUTANTS; BENZENE; EXPOSURES; POLLUTION; CLIMATE; CHINA;
D O I
10.1177/1420326X19833118
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the field measurement and evaluation of the indoor air quality of 25 naturally ventilated residential buildings in northwestern China. Concentrations of formaldehyde, benzene, toluene, total volatile organic compounds, nitrogen dioxide and PM2.5, and air infiltration rate were measured in the bedroom, living room and kitchen of each building in different seasons. The results show that the concentration of formaldehyde can be used as a representative index of indoor gaseous pollutants, and that formaldehyde concentrations in various locations measured were highest in spring and lowest in autumn. PM2.5 concentration was the most important influencing factor of indoor air quality in winter, and concentration of outdoor PM2.5 was the key factor under hazy weather conditions. The median air infiltration rate was around 0.35 h(-1) in bedrooms and 0.8 h(-1) in kitchens, and these should be increased to 0.66 h(-1) and 1.6 h(-1), respectively, to provide acceptable indoor air quality in northwestern China. The findings obtained from this study can be used to understand where and how to improve the indoor air quality of naturally ventilated buildings in northwestern China. The data can also contribute to the development of a national database for improving residential ventilation, energy efficiency and indoor air quality.
引用
收藏
页码:1307 / 1323
页数:17
相关论文
共 50 条
  • [1] Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
    Wong, NH
    Huang, B
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (09) : 1115 - 1123
  • [2] Indoor air quality for residential buildings
    Sherman, M
    [J]. ASHRAE JOURNAL, 1999, 41 (05) : 26 - 30
  • [3] Indoor Air Quality in Naturally Ventilated Italian Classrooms
    Fuoco, Fernanda Carmen
    Stabile, Luca
    Buonanno, Giorgio
    Trassiera, Concepcion Vargas
    Massimo, Angelamaria
    Russi, Aldo
    Mazaheri, Mandana
    Morawska, Lidia
    Andrade, Alexandro
    [J]. ATMOSPHERE, 2015, 6 (11) : 1652 - 1675
  • [4] Indoor air quality in naturally ventilated dwellings in Spain
    Garcia-Ortega, Sonia
    Linares-Alemparte, Pilar
    [J]. INFORMES DE LA CONSTRUCCION, 2023, 75 (572)
  • [5] Indoor air-quality control by a fuzzy-reasoning machine in naturally ventilated buildings
    Dounis, AI
    Bruant, M
    Guarracino, G
    Michel, P
    Santamouris, M
    [J]. APPLIED ENERGY, 1996, 54 (01) : 11 - 28
  • [6] On-site measurements of ventilation performance and indoor air quality in naturally ventilated high-rise residential buildings in Hong Kong
    Ai, Z. T.
    Mak, C. M.
    Cui, D. J.
    [J]. INDOOR AND BUILT ENVIRONMENT, 2015, 24 (02) : 214 - 224
  • [7] Numerical evaluation of the effect of traffic pollution on indoor air quality of a naturally ventilated building
    Chang, TJ
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2002, 52 (09): : 1043 - 1053
  • [8] Fuzzy Evaluation of Thermal Comfort in Naturally Ventilated Residential Buildings in China
    WANG YiNIU TiancaiLIU JiapingXIAO YongqiangSchool of Environmental and Municipal EngineeringXian University of Architecture and TechnologyXianShaanxi ChinaSchool of ArchitectureXian University of Architecture and TechnologyXianShaanxi ChinaSchool of Physical EducationXian University of Architecture and TechnologyXianShaanxi China
    [J]. 湖南大学学报(自然科学版)., 2009, 36(S1) (自然科学版) - 74
  • [9] Indoor Thermal Environment in Different Generations of Naturally Ventilated Public Residential Buildings in Singapore
    Deng, Ji-Yu
    Wong, Nyuk Hien
    Hii, Daniel Jun Chung
    Yu, Zhongqi
    Tan, Erna
    Zhen, Meng
    Tong, Shanshan
    [J]. ATMOSPHERE, 2022, 13 (12)
  • [10] Fuzzy Evaluation of Thermal Comfort in Naturally Ventilated Residential Buildings in China
    WANG Yi1
    2.School of Architecture
    3.School of Physical Education
    [J]. 湖南大学学报(自然科学版), 2009, (S1) : 71 - 74