Measurement and evaluation of indoor air quality in naturally ventilated residential buildings

被引:41
|
作者
Yin, Haiguo [1 ,2 ]
Liu, Chunxue [1 ]
Zhang, Leiming [1 ]
Li, Angui [1 ]
Ma, Zhenjun [2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, 13 Yanta Rd, Xian 710055, Shaanxi, Peoples R China
[2] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW, Australia
关键词
Residential buildings; Natural ventilation; Indoor air quality; Pollutants; Air infiltration rate; Field measurement; INITIAL EMITTABLE CONCENTRATION; VOLATILE ORGANIC-COMPOUNDS; FORMALDEHYDE CONCENTRATIONS; OUTDOOR AIR; POLLUTANTS; BENZENE; EXPOSURES; POLLUTION; CLIMATE; CHINA;
D O I
10.1177/1420326X19833118
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the field measurement and evaluation of the indoor air quality of 25 naturally ventilated residential buildings in northwestern China. Concentrations of formaldehyde, benzene, toluene, total volatile organic compounds, nitrogen dioxide and PM2.5, and air infiltration rate were measured in the bedroom, living room and kitchen of each building in different seasons. The results show that the concentration of formaldehyde can be used as a representative index of indoor gaseous pollutants, and that formaldehyde concentrations in various locations measured were highest in spring and lowest in autumn. PM2.5 concentration was the most important influencing factor of indoor air quality in winter, and concentration of outdoor PM2.5 was the key factor under hazy weather conditions. The median air infiltration rate was around 0.35 h(-1) in bedrooms and 0.8 h(-1) in kitchens, and these should be increased to 0.66 h(-1) and 1.6 h(-1), respectively, to provide acceptable indoor air quality in northwestern China. The findings obtained from this study can be used to understand where and how to improve the indoor air quality of naturally ventilated buildings in northwestern China. The data can also contribute to the development of a national database for improving residential ventilation, energy efficiency and indoor air quality.
引用
收藏
页码:1307 / 1323
页数:17
相关论文
共 50 条
  • [41] Uncertainty in the measurement of indoor temperature and humidity in naturally ventilated dairy buildings as influenced by measurement technique and data variability
    Hempel, Sabrina
    Koenig, Marcel
    Menz, Christoph
    Janke, David
    Amon, Barbara
    Banhazi, Thomas M.
    Estelles, Fernando
    Amon, Thomas
    [J]. BIOSYSTEMS ENGINEERING, 2018, 166 : 58 - 75
  • [42] Acoustic Design Criteria in Naturally Ventilated Residential Buildings: New Research Perspectives by Applying the Indoor Soundscape Approach
    Torresin, Simone
    Albatici, Rossano
    Aletta, Francesco
    Babich, Francesco
    Oberman, Tin
    Kang, Jian
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [43] Indoor air quality and prevalence of asthma in office workers of a naturally ventilated antique building
    Rios, J.
    Boechat, J.
    Gottens, A.
    Ramos, C.
    Aquino, Neto F.
    Lapa e Silva, J.
    [J]. ALLERGY, 2008, 63 : 552 - 552
  • [44] FUZZY LOGIC CONTROLLER DEPLOYED FOR INDOOR AIR QUALITY CONTROL IN NATURALLY VENTILATED ENVIRONMENTS
    Jaradat, Mohammad Abdel Kareem
    Al-Nimr, Mohd A.
    [J]. JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (01): : 12 - 17
  • [45] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    [J]. INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [46] Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building
    Tong, Zheming
    Chen, Yujiao
    Malkawi, Ali
    Adamkiewicz, Gary
    Spengler, John D.
    [J]. ENVIRONMENT INTERNATIONAL, 2016, 89-90 : 138 - 146
  • [47] An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings
    Lai, A. C. K.
    Mui, K. W.
    Wong, L. T.
    Law, L. Y.
    [J]. ENERGY AND BUILDINGS, 2009, 41 (09) : 930 - 936
  • [49] Smart ventilation energy and indoor air quality performance in residential buildings: A review
    Guyot, Gaelle
    Sherman, Max H.
    Walker, Iain S.
    [J]. ENERGY AND BUILDINGS, 2018, 165 : 416 - 430
  • [50] Indoor and outdoor air quality investigation at six residential buildings in Hong Kong
    Lee, Shun-Cheng
    Chang, Maureen
    Chan, Ka-Yee
    [J]. Environment International, 1999, 25 (04): : 489 - 496