Good indoor air quality (IAQ) in schools and tertiary institutions provides a comfortable and healthy environment for the students and staff to learn and work in, respectively. Hence, it is important to ascertain the IAQ status in the learning environment. This paper presents the development and application of an IAQ audit methodology for the tertiary institutional buildings. A staff room and a typical lecture theatre in a tertiary institution were selected for this study to present the IAQ status in premises with different occupancy pattern and internal loads. The IAQ audit consists of monitoring of thermal comfort parameters, microbial counts, dust particles and the concentrations of carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (HCHO) and total volatile organic compounds (TVOCs). Air exchange rate, ventilation effectiveness and age of air were also investigated. In addition, questionnaires were completed by the staff and students in order to provide a subjective assessment of the indoor air quality. The IAQ results collated in this study will be used to develop an IAQ database for institutional buildings in Singapore. This will be beneficial to the development of guidelines for good indoor air quality in institutional buildings. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
下载
收藏
页码:605 / 616
页数:12
相关论文
共 50 条
  • [1] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [2] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [3] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [4] EFFECT OF SPRING GRASS FIRES ON INDOOR AIR QUALITY IN AIR-CONDITIONED OFFICE BUILDING
    Pauraite, J.
    Garbariene, I.
    Minderyte, A.
    Dudoitis, V.
    Mainelis, G.
    Davuliene, L.
    Uoginte, I.
    Plauskaite, K.
    Bycenkiene, S.
    LITHUANIAN JOURNAL OF PHYSICS, 2021, 61 (03): : 191 - 204
  • [5] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [6] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [7] Ionization of air in an air-conditioned building
    Behounek, F
    Kletschka, J
    NATURE, 1938, 142 : 956 - 956
  • [8] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [9] Adaptive PID Control of Indoor Air Quality for an Air-conditioned Room
    Gu, Xiaosong
    Li, Heng
    Zhao, Litie
    Wang, Hanqing
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL 1, PROCEEDINGS, 2008, : 289 - +
  • [10] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274