Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics

被引:36
|
作者
Cheong, KWD [1 ]
Lau, HYT [1 ]
机构
[1] Natl Univ Singapore, Sch Design & Environm, Dept Bldg, Singapore 117566, Singapore
关键词
development; indoor air quality audit; institutional; tropics; methodology;
D O I
10.1016/S0360-1323(02)00183-X
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Good indoor air quality (IAQ) in schools and tertiary institutions provides a comfortable and healthy environment for the students and staff to learn and work in, respectively. Hence, it is important to ascertain the IAQ status in the learning environment. This paper presents the development and application of an IAQ audit methodology for the tertiary institutional buildings. A staff room and a typical lecture theatre in a tertiary institution were selected for this study to present the IAQ status in premises with different occupancy pattern and internal loads. The IAQ audit consists of monitoring of thermal comfort parameters, microbial counts, dust particles and the concentrations of carbon dioxide (CO2), carbon monoxide (CO), formaldehyde (HCHO) and total volatile organic compounds (TVOCs). Air exchange rate, ventilation effectiveness and age of air were also investigated. In addition, questionnaires were completed by the staff and students in order to provide a subjective assessment of the indoor air quality. The IAQ results collated in this study will be used to develop an IAQ database for institutional buildings in Singapore. This will be beneficial to the development of guidelines for good indoor air quality in institutional buildings. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
下载
收藏
页码:605 / 616
页数:12
相关论文
共 50 条
  • [31] METHODS OF IMPROVING AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1973, 15 (06): : 29 - 36
  • [32] Indoor air quality investigation at air-conditioned and non-airconditioned markets in Hong Kong
    Guo, H
    Lee, SC
    Chan, LY
    SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 323 (1-3) : 87 - 98
  • [33] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [34] A Numerical Study of the Indoor Thermal Environment in an Air-conditioned Large Space Building
    Liu Jiying
    PROCEEDINGS OF 8TH INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION (ICICTA 2015), 2015, : 69 - 72
  • [35] Microbial Air Quality in Air-conditioned Passenger Cars
    Golofit-Szymczak, Malgorzata
    Stobnicka-Kupiec, Agata
    ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 1564 - 1582
  • [36] Screening Strategies of an Indoor Air Quality Express Assessment Protocol (EAP) for Air-conditioned Offices
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (01) : 77 - 82
  • [37] FIELD STUDY OF AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL, 1971, 13 (01): : 55 - &
  • [38] Indoor air quality comparison of two air-conditioned zones served by the same air-handling unit
    Tham, KW
    Sekhar, SC
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (10) : 947 - 960
  • [39] Relationship of multiple indoor air pollutants and sick building syndrome at air-conditioned office buildings in Taiwan
    Wu, PC
    Li, YY
    Chiang, CM
    Su, HJ
    Lee, CC
    EPIDEMIOLOGY, 2004, 15 (04) : S16 - S16
  • [40] Development of air purification system in air-conditioned spaces
    Kwan, CHS
    Chan, DWT
    Law, LKC
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3430 - 3434