Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality

被引:4
|
作者
Prasad, RK
Uma, R
Kansal, A
Gupta, S
Kumar, P
Saksena, S
机构
[1] East West Ctr, Honolulu, HI 96848 USA
[2] AsianPaints, New Delhi, India
[3] Tata Energy Res Inst, New Delhi 110003, India
[4] GGS Indraprastha Univ, New Delhi, India
关键词
indoor air pollution; outdoor air pollution; ventilation; noise; air handling unit;
D O I
10.1159/0000068234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In an urban city like Delhi, vehicular exhaust is a major source of air pollution in addition to industrial activities emitting uncontrolled air pollutants. This contaminated air is sucked into buildings by air handling units contaminating the indoor air. In addition, indoor air is further contaminated by sources used for cooking, space heating devices, various chemicals and so on. The present paper analyses the indoor and outdoor air quality in a commercial building. The functioning of the air handling unit was also studied in the context of indoor air quality. Pollutants such as asbestos, carbon monoxide, formaldehyde, lead, oxides of nitrogen, ozone, respirable suspended particulates, sulphur dioxide and suspended particulate matter and gases such as oxygen and carbon dioxide were monitored. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [41] Indoor air quality maintenance in an air conditioned building using computational fluid dynamics
    Robin, JR
    Kalaiselvam, S
    Iniyan, S
    Samuel, AA
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 599 - 602
  • [42] AIR QUALITY IN AIR-CONDITIONED SPACES - ARE WE DOING A GOOD JOB
    SWANTON, JR
    ASHRAE JOURNAL, 1970, 12 (01): : 53 - &
  • [43] Indoor suspended particulates distribution in an air-conditioned teaching building
    Huang, YC
    Yang, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1807 - 1810
  • [44] INDOOR/OUTDOOR AIR POLLUTANT RELATIONSHIPS FOR AIR-CONDITIONED BUILDINGS
    YOCUM, JE
    COTE, WA
    ASHRAE JOURNAL, 1971, 13 (01): : 54 - &
  • [45] Feasibility study of an indoor air quality measurement protocol on 12 parameters in mechanically ventilated and air-conditioned buildings
    Chao, CY
    Chan, GY
    Ho, L
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (01) : 3 - 19
  • [46] Radon and its decay products in an air-conditioned auditorium in correlation with indoor air parameters
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (05) : 621 - 630
  • [47] Optimization of Indoor Air Quality Characteristics in an Air-Conditioned Car Using Multi-objective Genetic Algorithm
    Thirumal, P.
    Amirthagadeswaran, K. S.
    Jayabal, S.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (11) : 8307 - 8317
  • [48] Comparison of indoor air quality in restaurant kitchens in Tehran with ambient air quality
    Ghasemkhani, M.
    Naseri, F.
    IRANIAN JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE & ENGINEERING, 2008, 5 (01) : 59 - 64
  • [49] Optimization of Indoor Air Quality Characteristics in an Air-Conditioned Car Using Multi-objective Genetic Algorithm
    P. Thirumal
    K. S. Amirthagadeswaran
    S. Jayabal
    Arabian Journal for Science and Engineering, 2014, 39 : 8307 - 8317
  • [50] DISINFECTING AIR-CONDITIONED AIR
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +