Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality

被引:4
|
作者
Prasad, RK
Uma, R
Kansal, A
Gupta, S
Kumar, P
Saksena, S
机构
[1] East West Ctr, Honolulu, HI 96848 USA
[2] AsianPaints, New Delhi, India
[3] Tata Energy Res Inst, New Delhi 110003, India
[4] GGS Indraprastha Univ, New Delhi, India
关键词
indoor air pollution; outdoor air pollution; ventilation; noise; air handling unit;
D O I
10.1159/0000068234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In an urban city like Delhi, vehicular exhaust is a major source of air pollution in addition to industrial activities emitting uncontrolled air pollutants. This contaminated air is sucked into buildings by air handling units contaminating the indoor air. In addition, indoor air is further contaminated by sources used for cooking, space heating devices, various chemicals and so on. The present paper analyses the indoor and outdoor air quality in a commercial building. The functioning of the air handling unit was also studied in the context of indoor air quality. Pollutants such as asbestos, carbon monoxide, formaldehyde, lead, oxides of nitrogen, ozone, respirable suspended particulates, sulphur dioxide and suspended particulate matter and gases such as oxygen and carbon dioxide were monitored. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [21] FIELD STUDY OF AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL, 1971, 13 (01): : 55 - &
  • [22] An implementation choice of assessment parameters for indoor air quality (IAQ) in air-conditioned offices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    Chan, W-Y.
    FACILITIES, 2009, 27 (5-6) : 202 - 210
  • [23] Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
    Hui, Pui-Shan
    Mui, Kwok-Wai
    Wong, Ling-Tim
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 144 (1-3) : 315 - 322
  • [24] Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (04) : 373 - 378
  • [25] Indoor Environmental Quality Benchmarks for Air-conditioned Offices in the Subtropics
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 123 - 129
  • [26] Evaluation of the neutral criterion of indoor air quality for air-conditioned offices in subtropical climates
    Mui, K. W.
    Wong, L. T.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (01): : 23 - 33
  • [27] Indoor air quality comparison of two air-conditioned zones served by the same air-handling unit
    Tham, KW
    Sekhar, SC
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (10) : 947 - 960
  • [28] Outdoor pollutants effect on air quality of air-conditioned room
    Zheng, Jianxiang
    Zhou, Lei
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 1379 - 1384
  • [29] Indoor air quality investigation at air-conditioned and non-airconditioned markets in Hong Kong
    Guo, H
    Lee, SC
    Chan, LY
    SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 323 (1-3) : 87 - 98
  • [30] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8