Determination of patient set-up error and optimal treatment margin for intensity modulated radiotherapy using image guidance system

被引:5
|
作者
Kanakavelu, Nithya [1 ,2 ]
Samuel, James Jebaseelan [2 ]
机构
[1] Medwin Canc Ctr, Dept Radiat Oncol, Hyderabad, Andhra Pradesh, India
[2] VIT Univ, Photon Nucl & Med Phys Div, Vellore 632014, Tamil Nadu, India
来源
JOURNAL OF BUON | 2016年 / 21卷 / 02期
关键词
image guided radiotherapy; intensity modulated radiotherapy; patient set-up errors; DOSIMETRIC CONSEQUENCES; QUALITY-ASSURANCE; PTV MARGIN; HEAD; IMRT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The geometrical uncertainties in the patient positioning during intensity modulated radiotherapy (IMRT) are crucial as there is potential to underdose the tumor and overdose the nearby critical structures. Image guided techniques provide a solution to assess the patient set-up uncertainties and help determine the optimal planning target volume (PTV) margin to the clinical tumor volume (CTV). Methods: A retrospective study was conducted to evaluate patient set-up errors along the three translational directions at different treatment sites such as the brain, the head and neck (H&N) and the prostate. A total of 60 patients' set-up error data was analysed to evaluate the systematic and random errors and the optimal CTV-PTV margin. Results: For brain and H&N sites, more than 90, 80 and about 100% of the total image acquisitions were less than 3 mm in lateral, longitudinal and vertical directions respectively. For the prostate cases, the frequency of patient set-up error to be less than 3 mm were 79.7, 75.6 and 80% in lateral, longitudinal and vertical directions respectively. About 0.6% had more than 7 mm error in the lateral and longitudinal directions for the prostate site. CTV-PTV margin of 3.4, 3.4 and 1.9 mm for brain cases, 3.5, 3 and 1.8 mm for H&N cases and 5, 4.6 and 4.5 mm for the prostate cases in the lateral, longitudinal and vertical directions respectively were determined. Conclusion: Image guidance is an effective method to evaluate the accuracy of IMRT treatment delivery. The optimal CTV-PTV margin can be determined to ensure adequate dose to CTV, specific to the site.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [1] A method for patient set-up guidance in radiotherapy using augmented reality
    J. Talbot
    J. Meyer
    R. Watts
    R. Grasset
    Australasian Physical & Engineering Sciences in Medicine, 2009, 32 : 203 - 211
  • [2] Margin evaluation of translational and rotational set-up errors in intensity modulated radiotherapy for cervical cancer
    Zhang, Xiang
    Shan, Guo-ping
    Liu, Ji-ping
    Wang, Bin-bing
    SPRINGERPLUS, 2016, 5 : 1 - 9
  • [3] A method for patient set-up guidance in radiotherapy using augmented reality
    Talbot, J.
    Meyer, J.
    Watts, R.
    Grasset, R.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) : 203 - 211
  • [4] Calculation of set-up margin in frameless stereotactic radiotherapy accounting for translational and rotational patient positing error
    Manikandan, Arjunan
    Sarkar, Biplab
    Munshi, Anusheel
    Krishnankutty, Saneg
    Ganesh, Tharmarnadar
    Mohanti, Bidhu Kalyan
    Manikandan, Sujatha
    Anirudh, Pradhan
    Chandrasekharan, Surekha
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (02) : 169 - 176
  • [5] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156
  • [6] A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy
    Hector, C
    Webb, S
    Evans, PM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05): : 1451 - 1471
  • [7] Patient set-up in radiotherapy with video-based positioning system
    Tao, S
    Wu, A
    Wu, Y
    Chen, Y
    Zhang, J
    CLINICAL ONCOLOGY, 2006, 18 (04) : 363 - 366
  • [8] An Evaluation of Translational Set-Up Errors to Define An Institutional Protocol for Set-Up Margins in the Treatment of Cancer Cervix Using Image Guided Radiotherapy (IGRT)
    Rani, G.
    Kaur, H.
    Ninan, J.
    Chandrasenan, P.
    Abdussameeh, M. P.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Elimination of the Set-Up Margin Using Daily Adaptive Radiotherapy for Head and Neck Radiotherapy: A Feasibility Study
    Lin, M.
    Park, J.
    Zhong, X.
    Chen, L.
    Morgan, H.
    Trivedi, Z.
    Godley, A.
    Pompos, A.
    Jiang, S.
    Sher, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Accuracy and efficiency of an infrared based positioning and tracking system for patient set-up and monitoring in image guided radiotherapy
    Jia, Jing
    Xu, Gongming
    Pei, Xi
    Cao, Ruifen
    Hu, Liqin
    Wu, Yican
    INFRARED PHYSICS & TECHNOLOGY, 2015, 69 : 26 - 31