Determination of patient set-up error and optimal treatment margin for intensity modulated radiotherapy using image guidance system

被引:5
|
作者
Kanakavelu, Nithya [1 ,2 ]
Samuel, James Jebaseelan [2 ]
机构
[1] Medwin Canc Ctr, Dept Radiat Oncol, Hyderabad, Andhra Pradesh, India
[2] VIT Univ, Photon Nucl & Med Phys Div, Vellore 632014, Tamil Nadu, India
来源
JOURNAL OF BUON | 2016年 / 21卷 / 02期
关键词
image guided radiotherapy; intensity modulated radiotherapy; patient set-up errors; DOSIMETRIC CONSEQUENCES; QUALITY-ASSURANCE; PTV MARGIN; HEAD; IMRT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The geometrical uncertainties in the patient positioning during intensity modulated radiotherapy (IMRT) are crucial as there is potential to underdose the tumor and overdose the nearby critical structures. Image guided techniques provide a solution to assess the patient set-up uncertainties and help determine the optimal planning target volume (PTV) margin to the clinical tumor volume (CTV). Methods: A retrospective study was conducted to evaluate patient set-up errors along the three translational directions at different treatment sites such as the brain, the head and neck (H&N) and the prostate. A total of 60 patients' set-up error data was analysed to evaluate the systematic and random errors and the optimal CTV-PTV margin. Results: For brain and H&N sites, more than 90, 80 and about 100% of the total image acquisitions were less than 3 mm in lateral, longitudinal and vertical directions respectively. For the prostate cases, the frequency of patient set-up error to be less than 3 mm were 79.7, 75.6 and 80% in lateral, longitudinal and vertical directions respectively. About 0.6% had more than 7 mm error in the lateral and longitudinal directions for the prostate site. CTV-PTV margin of 3.4, 3.4 and 1.9 mm for brain cases, 3.5, 3 and 1.8 mm for H&N cases and 5, 4.6 and 4.5 mm for the prostate cases in the lateral, longitudinal and vertical directions respectively were determined. Conclusion: Image guidance is an effective method to evaluate the accuracy of IMRT treatment delivery. The optimal CTV-PTV margin can be determined to ensure adequate dose to CTV, specific to the site.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 50 条
  • [41] Assessment of set-up discrepancies using daily portal imaging during radiotherapy treatment for patients with spine and bone metastases
    Young, L.
    Blyth, C. M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2012, 11 (04) : 209 - 216
  • [42] Determination of Patient Setup Error in Radiotherapy using Feature-Based Multimodal Rigid Image Registration
    Hakim, Aayesha
    Talele, K. T. V.
    Harsh, Rajesh
    Verma, Dharmesh
    2015 IEEE BOMBAY SECTION SYMPOSIUM (IBSS), 2015,
  • [43] Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a 60Co Magnetic Resonance Image Guidance Radiation Therapy System
    Wooten, H. Omar
    Green, Olga
    Yang, Min
    DeWees, Todd
    Kashani, Rojano
    Olsen, Jeff
    Michalski, Jeff
    Yang, Deshan
    Tanderup, Kari
    Hu, Yanle
    Li, H. Harold
    Mutic, Sasa
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 92 (04): : 771 - 778
  • [44] DOSIMETRIC EFFECT OF INTRAFRACTION MOTION AND RESIDUAL SETUP ERROR FOR HYPOFRACTIONATED PROSTATE INTENSITY-MODULATED RADIOTHERAPY WITH ONLINE CONE BEAM COMPUTED TOMOGRAPHY IMAGE GUIDANCE
    Adamson, Justus
    Wu, Qiuwen
    Yan, Di
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (02): : 453 - 461
  • [45] Optimal gantry angles and field sizes in kilovoltage cone-beam tomosynthesis for set-up of women with breast cancer undergoing radiotherapy treatment
    Lyatskaya, Yulia
    Buehler, Andreas
    Ng, Sook-Kien
    Wong, Julia
    Bellon, Jennifer R.
    Zygmanski, Piotr
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 633 - 638
  • [46] An Exploratory Study on Obtaining Optimal Parameters Of Intensity Modulated Radiotherapy Treatment Plans For Breast Cancer Using Ideal DVH
    Lin, X.
    Yin, Y.
    Sun, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E500 - E500
  • [47] Development of a New Patient Set-Up Monitoring System Using Force Sensing Resistor (FSR) Sensor for the Radiation Therapy
    Cho, M.
    Kim, T.
    Kang, S.
    Kim, D.
    Kim, K.
    Shin, D.
    Suh, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3392 - 3392
  • [48] Improving the set-up of breast cancer patients during radiation treatment using an optical surface scanning system
    Thornberg, C.
    Kugele, M.
    Edvardsson, A.
    Ceberg, S.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S222 - S222
  • [49] Stereotactic image-guided intensity modulated radiotherapy using the HI-ART II helical tomotherapy system
    Holmes, Timothy W.
    Hudes, Richard
    Dziuba, Sylwester
    Kazi, Abdul
    Hall, Mark
    Dawson, Dana
    MEDICAL DOSIMETRY, 2008, 33 (02) : 135 - 148
  • [50] Daily Image Guidance with Cone-beam Computer Tomography Reduces Setup Margin Compared with 2D Megavoltage Imaging for Head and Neck Intensity Modulated Radiotherapy
    Tanzler, E.
    Samant, S.
    Liu, C.
    Amdur, R. J.
    Mendenhall, W. M.
    Yeung, A. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S175 - S176