Margin evaluation of translational and rotational set-up errors in intensity modulated radiotherapy for cervical cancer

被引:8
|
作者
Zhang, Xiang [1 ,3 ]
Shan, Guo-ping [2 ,3 ]
Liu, Ji-ping [2 ,3 ]
Wang, Bin-bing [2 ,3 ]
机构
[1] Zhejiang Canc Hosp, Dept Gynecol Radiat Oncol, Hangzhou 310022, Zhejiang, Peoples R China
[2] Zhejiang Canc Hosp, Dept Radiat Phys, Hangzhou 310022, Zhejiang, Peoples R China
[3] Zhejiang Key Lab Radiat Oncol, Hangzhou 310022, Zhejiang, Peoples R China
来源
SPRINGERPLUS | 2016年 / 5卷
关键词
Rotational set-up errors; Image-guided radiotherapy; Cervical cancer; Intensity modulated radiotherapy; CONE-BEAM-CT; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; CONVENTIONAL RADIOTHERAPY; PELVIC RADIOTHERAPY; VERIFICATION; PROSTATE; GUIDANCE; SYSTEM; FIELDS;
D O I
10.1186/s40064-016-1796-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A clinical target volume (CTV) to planning target volume (PTV) margin recipes was routinely used to ensure dose was actually delivered to target for all (most) patients. Currently used margin recipes were associated with only translational set-up errors in radiotherapy. However, when set-up errors extended to six-degree (6D) scope (three translational and three rotational set-up errors), margin recipe should be re-evaluated. The purpose of this study was to investigate dosimetric changes of targets (both CTV and PTV) coverage when 6D set-up errors were introduced and testify the practicability of currently used margin recipe in radiotherapy. A total number of 105 cone beam computer tomography scans for ten patients with cervical cancer were derived prior to treatment delivery and 6D set-up errors were acquired with image registration tools. Target coverage was evaluated retrospectively for 6D set-up errors introduced plan with 6 mm CTV to PTV margin. Target coverage of PTV showed significant decreases (3.3 %) in set-up errors introduced plans compared with original plans. But CTV coverage was not susceptible to these set-up errors. A tendency of coverage decrease for PTV along with distance away from treatment was testified, from -0.2 to -6.2 %. However, CTV seems changed less, from -0.2 to -0.8 %. The result indicate that a CTV to PTV margin of 6 mm was sufficient to take into account 6D set-up errors for most patients with cervical cancer. Future research suggests a smaller margin to further improve both tumor coverage and organs at risk sparing.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Evaluation of set-up errors and determination of set-up margin in pelvic radiotherapy by electronic portal imaging device (EPID)
    Noghreiyan, Vajiheh Vejdani
    Nasseri, Shahrookh
    Anvari, Kazem
    Naji, Maryam
    Momennezhad, Mehdi
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (02) : 150 - 156
  • [2] Calculation of set-up margin in frameless stereotactic radiotherapy accounting for translational and rotational patient positing error
    Manikandan, Arjunan
    Sarkar, Biplab
    Munshi, Anusheel
    Krishnankutty, Saneg
    Ganesh, Tharmarnadar
    Mohanti, Bidhu Kalyan
    Manikandan, Sujatha
    Anirudh, Pradhan
    Chandrasekharan, Surekha
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (02) : 169 - 176
  • [3] An Evaluation of Translational Set-Up Errors to Define An Institutional Protocol for Set-Up Margins in the Treatment of Cancer Cervix Using Image Guided Radiotherapy (IGRT)
    Rani, G.
    Kaur, H.
    Ninan, J.
    Chandrasenan, P.
    Abdussameeh, M. P.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Set-up errors due to endorectal balloon positioning in intensity modulated radiation therapy for prostate cancer
    Wang, Chun-Wei
    Chong, Fok-Ching
    Lai, Ming-Kuen
    Pu, Yeong-Shiau
    Wu, Jian-Kuen
    Cheng, Jason Chia-Hsien
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 (02) : 177 - 184
  • [5] Determination of patient set-up error and optimal treatment margin for intensity modulated radiotherapy using image guidance system
    Kanakavelu, Nithya
    Samuel, James Jebaseelan
    JOURNAL OF BUON, 2016, 21 (02): : 505 - 511
  • [6] Adaptive set-up correction (ASC) to account for set-up errors in prostate radiotherapy
    Lauve, A
    Siebers, J
    Crimaldi, A
    Hagan, M
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S332 - S332
  • [7] Residual rotational set-up errors after daily cone-beam CT image guided radiotherapy of locally advanced cervical cancer
    Laursen, Louise Vagner
    Elstrom, Ulrik Vindelev
    Vestergaard, Anne
    Muren, Ludvig P.
    Petersen, Jorgen Baltzer
    Lindegaard, Jacob Christian
    Grau, Cai
    Tanderup, Kari
    RADIOTHERAPY AND ONCOLOGY, 2012, 105 (02) : 220 - 225
  • [8] Construction of Prediction Model of Radiotherapy Set-Up Errors in Patients with Lung Cancer
    Yang, Fan
    Li, Xinxia
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [9] The effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer
    Cao, X.
    Liu, M.
    Zhai, F.
    Li, N.
    Bao, C.
    Liu, Y.
    Chen, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (03): : 515 - 520
  • [10] Translational and rotational set-up uncertainties in Head and Neck cancer treatments using CBCT
    Di Biase, M.
    Trignani, M.
    Caponigro, G.
    Di Pilla, A.
    Perrotti, F.
    Augurio, A.
    Giancaterino, S.
    Bagala, P.
    Falco, M. D.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S835 - S836