Margin evaluation of translational and rotational set-up errors in intensity modulated radiotherapy for cervical cancer

被引:8
|
作者
Zhang, Xiang [1 ,3 ]
Shan, Guo-ping [2 ,3 ]
Liu, Ji-ping [2 ,3 ]
Wang, Bin-bing [2 ,3 ]
机构
[1] Zhejiang Canc Hosp, Dept Gynecol Radiat Oncol, Hangzhou 310022, Zhejiang, Peoples R China
[2] Zhejiang Canc Hosp, Dept Radiat Phys, Hangzhou 310022, Zhejiang, Peoples R China
[3] Zhejiang Key Lab Radiat Oncol, Hangzhou 310022, Zhejiang, Peoples R China
来源
SPRINGERPLUS | 2016年 / 5卷
关键词
Rotational set-up errors; Image-guided radiotherapy; Cervical cancer; Intensity modulated radiotherapy; CONE-BEAM-CT; IMAGE-GUIDED RADIOTHERAPY; RADIATION-THERAPY; CONVENTIONAL RADIOTHERAPY; PELVIC RADIOTHERAPY; VERIFICATION; PROSTATE; GUIDANCE; SYSTEM; FIELDS;
D O I
10.1186/s40064-016-1796-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A clinical target volume (CTV) to planning target volume (PTV) margin recipes was routinely used to ensure dose was actually delivered to target for all (most) patients. Currently used margin recipes were associated with only translational set-up errors in radiotherapy. However, when set-up errors extended to six-degree (6D) scope (three translational and three rotational set-up errors), margin recipe should be re-evaluated. The purpose of this study was to investigate dosimetric changes of targets (both CTV and PTV) coverage when 6D set-up errors were introduced and testify the practicability of currently used margin recipe in radiotherapy. A total number of 105 cone beam computer tomography scans for ten patients with cervical cancer were derived prior to treatment delivery and 6D set-up errors were acquired with image registration tools. Target coverage was evaluated retrospectively for 6D set-up errors introduced plan with 6 mm CTV to PTV margin. Target coverage of PTV showed significant decreases (3.3 %) in set-up errors introduced plans compared with original plans. But CTV coverage was not susceptible to these set-up errors. A tendency of coverage decrease for PTV along with distance away from treatment was testified, from -0.2 to -6.2 %. However, CTV seems changed less, from -0.2 to -0.8 %. The result indicate that a CTV to PTV margin of 6 mm was sufficient to take into account 6D set-up errors for most patients with cervical cancer. Future research suggests a smaller margin to further improve both tumor coverage and organs at risk sparing.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Dose escalated intensity modulated radiotherapy in the treatment of cervical cancer
    Nikola Cihoric
    Alexandros Tsikkinis
    Coya Tapia
    Daniel M. Aebersold
    Inti Zlobec
    Kristina Lössl
    Radiation Oncology, 10
  • [42] STATISTICAL EVALUATION OF SET-UP ERRORS IN THE ARC/SPAR SYSTEM.
    Sheldon, D.D.
    McKenzie, J.M.
    Nuclear materials management, 1985, 14 (03): : 402 - 404
  • [43] Comparing intensity modulated radiotherapy and conventional external beam radiotherapy in cervical cancer
    Gudipudi, Deleep Kumar
    Alluri, Krishnam Raju
    De Leon, Maria B.
    Cardenes, Higinia Rosa
    Del Priore, Giuseppe
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (15)
  • [44] INFLUENCE OF COMPUTER-SIMULATED SET-UP ERRORS ON DOSE DISTRIBUTIONS IN EXTERNAL RADIOTHERAPY
    ROSENOW, U
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 135 - 135
  • [45] The importance of communication skills required to reduce set-up errors in the radiotherapy planning phase
    Merlotti, A.
    Reali, A.
    Russi, E.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (04) : 395 - 396
  • [46] Robustness to set-up errors for treatment plans for superficial tumors in head and neck radiotherapy
    Den Boer, D.
    Slooten, E.
    Wortel, G.
    Lamers-Kuijper, E.
    Hamming-Vrieze, O.
    Van Vliet-Vroegindeweij, C.
    Damen, E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S773 - S773
  • [47] The potential impact of the tension of the pelvic muscles on set-up errors in radiotherapy for pelvic malignancies
    Bujko, K
    Czuchraniuk, P
    Zólciak, A
    Kukolowicz, P
    Kepka, L
    Bielik, A
    ACTA ONCOLOGICA, 2004, 43 (08) : 740 - 743
  • [48] Image-guided radiation therapy for carcinoma of gallbladder: implication on margin for set-up errors
    Saini, Gagan
    Goel, Vineeta
    Anand, Anil K.
    Gupta, Kamlesh Kumar
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (03) : 263 - 271
  • [49] Prospective evaluation of the setup errors and its impact on safety margin for cervical cancer pelvic conformal radiotherapy
    Badajena, Avinash
    Raturi, Vijay Parshuram
    Sirvastava, Kirti
    Hojo, Hidehiro
    Ohyoshi, Hajime
    Bei, Yanping
    Rachi, Toshiya
    Wu, Chen-Ta
    Tochinai, Taku
    Okumura, Masayuki
    Zhang, Haiqin
    Kouta, Hirotaki
    Verma, Pragya
    Singh, Geeta
    Anand, Abhishek
    Sachan, Anjali
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (02) : 260 - 265
  • [50] The Importance of inter-and intra-fractional Motion and residual set-up Errors for the Evaluation of PTV Safety margins in Radiotherapy of Prostate cancer
    Langsenlehner, T.
    Doeller, C.
    Winkler, P.
    Galle, G.
    Kapp, K. S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (02) : 178 - 178