Performance Evaluation of an Adsorption Heat Pump System Using MSC-30/R1234yf Pair with the Impact of Thermal Masses

被引:3
|
作者
Seo, Sangwon [1 ]
Miksik, Frantisek [1 ,2 ]
Maeshiro, Yuta [1 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
机构
[1] Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 05期
关键词
adsorption heat pump cycle; isotherm fitting; activated carbon; MSC-30; R1234yf; ACTIVATED CARBON; SILICA-GEL; THERMODYNAMIC PROPERTIES; PHYSICAL ADSORPTION; WATER-ADSORPTION; COMPOSITE; ADSORBENT; DIFLUOROMETHANE; SIMULATION; ISOTHERMS;
D O I
10.3390/app11052279
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we evaluated the performance of low Global Warming Potential (GWP) refrigerant R1234yf on the activated carbon (MSC-30) for adsorption heating applications. The adsorption isotherms of MSC-30/R1234yf were measured using a constant-volume-variable-pressure (CVVP) method from very low relative pressure to the practical operating ranges. The data were fitted with several isotherm models using non-linear curve fitting. An improved equilibrium model was employed to investigate the influence of dead thermal masses, i.e., the heat exchanger assembly and the non-adsorbing part of the adsorbent. The model employed the model for the isosteric heat of adsorption where the adsorbed phase volume was accounted for. The performance of the heat pump was compared with MSC-30/R134a pair using the data from the literature. The analysis covered the desorption temperature ranging from 60 degrees C to 90 degrees C, with the evaporation temperature at 5 degrees C and the adsorption temperature and condensation temperature set to 30 degrees C. It was observed that the adsorption isotherms of R1234yf on MSC-30 were relatively lower than those of R134a by approximately 12%. The coefficient of performance (COP) of the selected pair was found to vary from 0.03 to 0.35 depending on the heat source temperature. We demonstrated that due to lower latent heat, MSC-30/R1234yf pair exhibits slightly lower cycle performance compared to the MSC-30/R134a pair. However, the widespread adaptation of environmentally friendly R1234yf in automobile heat pump systems may call for the implementation of adsorption systems such as the direct hybridization using a single refrigerant. The isotherm and performance data presented in this work will be essential for such applications.
引用
收藏
页码:1 / 25
页数:24
相关论文
共 50 条
  • [21] Predicting the energetic performance of an automobile heat pump utilising a fixed capacity compressor and R1234yf using ANN modelling
    Alkan, Alpaslan
    Koc, Mehmet Akif
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 170 : 363 - 384
  • [22] Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)
    Bosnjakovic, Mladen
    Santa, Robert
    Katinic, Marko
    SUSTAINABILITY, 2023, 15 (11)
  • [23] Experimental study of the integrated vapor injection R1234yf electric vehicle heat pump system in cold conditions
    Ji, Zhiyuan
    Wang, Haimin
    Fu, Meiya
    Lin, Chunjing
    Xu, Yifeng
    Jiang, Yixin
    APPLIED THERMAL ENGINEERING, 2025, 270
  • [24] EMPIRICAL CORRELATIONS FOR THE PERFORMANCE OF AN AUTOMOTIVE AIR CONDITIONING SYSTEM USING R1234yf AND R134a
    Aral, Mumin Celil
    Hosoz, Murat
    Subermanto, Mukhamad
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2017, 37 (01) : 127 - 137
  • [25] Performance evaluation of VCR system with pure and various blends of R134a, R1234yf, and R1234ze (E) refrigerants
    Kuwar, Yogendra Vasantrao
    HEAT TRANSFER, 2024, 53 (06) : 2879 - 2904
  • [26] Performance of Automotive Ultra-Low Temperature Economized Vapor Injection Heat Pump Air Conditioning Using R1234yf Refrigerant
    Liu Y.
    Li W.
    Zhang L.
    Shi J.
    Chen J.
    Chen, Jiangping (jpchen_sjtu@163.com), 2020, Shanghai Jiaotong University (54): : 1108 - 1116
  • [27] Gaseous solubility and thermodynamic performance of absorption system using R1234yf/IL working pairs
    Sun, Yanjun
    Di, Gaolei
    Wang, Jian
    Hu, Yusheng
    Wang, Xiaopo
    He, Maogang
    APPLIED THERMAL ENGINEERING, 2020, 172 (172)
  • [28] Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan, Angel
    Moles, Francisco
    Peris, Bernardo
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 259 - 265
  • [29] Energy and environment analysis of R1234yf/R245fa cascade air source heat pump system with double ejectors
    Li, Jing
    Li, Minxia
    Dang, Chaobin
    Wang, Qifan
    Dong, Liwei
    Liu, Xuetao
    ENERGY CONVERSION AND MANAGEMENT, 2025, 325
  • [30] Statistical analysis of the energy performance of a refrigeration system working with R1234yf using artificial neural networks
    Belman-Flores, J. M.
    Ledesma, Sergio