Performance Evaluation of an Adsorption Heat Pump System Using MSC-30/R1234yf Pair with the Impact of Thermal Masses

被引:3
|
作者
Seo, Sangwon [1 ]
Miksik, Frantisek [1 ,2 ]
Maeshiro, Yuta [1 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
机构
[1] Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 05期
关键词
adsorption heat pump cycle; isotherm fitting; activated carbon; MSC-30; R1234yf; ACTIVATED CARBON; SILICA-GEL; THERMODYNAMIC PROPERTIES; PHYSICAL ADSORPTION; WATER-ADSORPTION; COMPOSITE; ADSORBENT; DIFLUOROMETHANE; SIMULATION; ISOTHERMS;
D O I
10.3390/app11052279
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we evaluated the performance of low Global Warming Potential (GWP) refrigerant R1234yf on the activated carbon (MSC-30) for adsorption heating applications. The adsorption isotherms of MSC-30/R1234yf were measured using a constant-volume-variable-pressure (CVVP) method from very low relative pressure to the practical operating ranges. The data were fitted with several isotherm models using non-linear curve fitting. An improved equilibrium model was employed to investigate the influence of dead thermal masses, i.e., the heat exchanger assembly and the non-adsorbing part of the adsorbent. The model employed the model for the isosteric heat of adsorption where the adsorbed phase volume was accounted for. The performance of the heat pump was compared with MSC-30/R134a pair using the data from the literature. The analysis covered the desorption temperature ranging from 60 degrees C to 90 degrees C, with the evaporation temperature at 5 degrees C and the adsorption temperature and condensation temperature set to 30 degrees C. It was observed that the adsorption isotherms of R1234yf on MSC-30 were relatively lower than those of R134a by approximately 12%. The coefficient of performance (COP) of the selected pair was found to vary from 0.03 to 0.35 depending on the heat source temperature. We demonstrated that due to lower latent heat, MSC-30/R1234yf pair exhibits slightly lower cycle performance compared to the MSC-30/R134a pair. However, the widespread adaptation of environmentally friendly R1234yf in automobile heat pump systems may call for the implementation of adsorption systems such as the direct hybridization using a single refrigerant. The isotherm and performance data presented in this work will be essential for such applications.
引用
收藏
页码:1 / 25
页数:24
相关论文
共 50 条
  • [41] Energetic and exergetic performance comparison o an experimental automotive air conditioning system using refrigerants R1234yf and R134a
    Alkan, Alpaslan
    Kolip, Ahmet
    Hosoz, Murat
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (05): : 1163 - 1173
  • [42] Experimental analysis of the internal heat exchanger influence on a vapour compression system performance working with R1234yf as a drop-in replacement for R134a
    Navarro-Esbri, Joaquin
    Moles, Francisco
    Barragan-Cervera, Angel
    APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 153 - 161
  • [43] Thermal-hydraulic performance of R1234yf in brazed plate heat exchanger at low saturation temperature and mass flux conditions: Experimental investigation
    Salman, Mohammad
    Dhamodharan, Palanisamy
    Kim, Sung Chul
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [44] Energy and environmental performance of vapor injection heat pumps using R134a, R152a, and R1234yf under various injection conditions
    Maeng, Heegyu
    Kim, Jinyoung
    Kwon, Soonbum
    Kim, Yongchan
    ENERGY, 2023, 280
  • [45] Revolutionizing electric vehicle cooling: Optimal performance of R1234yf two-phase refrigerant cooling for EV battery thermal management system
    Dhamodharan, Palanisamy
    Salman, Mohammad
    Prabakaran, Rajendran
    Choi, Gyu Sang
    Kim, Sung Chul
    APPLIED THERMAL ENGINEERING, 2025, 260
  • [46] Performance evaluation of an absorption refrigeration system using R1234yf-organic absorbents working fluids
    Khelifa, Salhi
    Ramadan, Khaled
    Ammar, Mohammed Ali Hadj
    Mohammed Moundji, Hadjiat
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2021, 27 (07) : 936 - 947
  • [47] Performance evaluation of a heat pump system using an HFC32/HFO1234yf blend with GWP below 150 for heating applications
    Thu, Kyaw
    Takezato, Kosei
    Takata, Nobuo
    Miyazaki, Takahiko
    Higashi, Yukihiro
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [48] Comparative analysis of R290 and R1234yf cooling performance in offset strip-fin plate heat exchanger for electric-vehicle battery thermal management
    Dhamodharan, Palanisamy
    Salman, Mohammad
    Prabakaran, Rajendran
    Kim, Sung Chul
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 157
  • [49] Effect of Ambient Temperature on the Performance Characteristics of Automotive Air Conditioning System Using R1234yf and R134a: Energy and Exergy-based approaches
    Suhermanto, Mukhamad
    Hosoz, Murat
    Aral, M. Celil
    PROCEEDINGS OF THE INTERNATIONAL MECHANICAL ENGINEERING AND ENGINEERING EDUCATION CONFERENCES (IMEEEC-2016), 2016, 1778
  • [50] Experimental study on boiling heat transfer characteristics of RDR-1, R134a, and R1234yf over a wide temperature range and comparative analysis of their system performance
    Sun, Dahan
    Li, Ruijie
    Wang, Cong
    Liu, Zekuan
    Qin, Jiang
    Liu, Zhongyan
    APPLIED THERMAL ENGINEERING, 2024, 245