Performance Evaluation of an Adsorption Heat Pump System Using MSC-30/R1234yf Pair with the Impact of Thermal Masses

被引:3
|
作者
Seo, Sangwon [1 ]
Miksik, Frantisek [1 ,2 ]
Maeshiro, Yuta [1 ]
Thu, Kyaw [1 ,2 ]
Miyazaki, Takahiko [1 ,2 ]
机构
[1] Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
[2] Kyushu Univ, Int Inst Carbon Neutral Energy Res I2CNER, Res Ctr Next Generat Refrigerant Properties NEXT, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 05期
关键词
adsorption heat pump cycle; isotherm fitting; activated carbon; MSC-30; R1234yf; ACTIVATED CARBON; SILICA-GEL; THERMODYNAMIC PROPERTIES; PHYSICAL ADSORPTION; WATER-ADSORPTION; COMPOSITE; ADSORBENT; DIFLUOROMETHANE; SIMULATION; ISOTHERMS;
D O I
10.3390/app11052279
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we evaluated the performance of low Global Warming Potential (GWP) refrigerant R1234yf on the activated carbon (MSC-30) for adsorption heating applications. The adsorption isotherms of MSC-30/R1234yf were measured using a constant-volume-variable-pressure (CVVP) method from very low relative pressure to the practical operating ranges. The data were fitted with several isotherm models using non-linear curve fitting. An improved equilibrium model was employed to investigate the influence of dead thermal masses, i.e., the heat exchanger assembly and the non-adsorbing part of the adsorbent. The model employed the model for the isosteric heat of adsorption where the adsorbed phase volume was accounted for. The performance of the heat pump was compared with MSC-30/R134a pair using the data from the literature. The analysis covered the desorption temperature ranging from 60 degrees C to 90 degrees C, with the evaporation temperature at 5 degrees C and the adsorption temperature and condensation temperature set to 30 degrees C. It was observed that the adsorption isotherms of R1234yf on MSC-30 were relatively lower than those of R134a by approximately 12%. The coefficient of performance (COP) of the selected pair was found to vary from 0.03 to 0.35 depending on the heat source temperature. We demonstrated that due to lower latent heat, MSC-30/R1234yf pair exhibits slightly lower cycle performance compared to the MSC-30/R134a pair. However, the widespread adaptation of environmentally friendly R1234yf in automobile heat pump systems may call for the implementation of adsorption systems such as the direct hybridization using a single refrigerant. The isotherm and performance data presented in this work will be essential for such applications.
引用
收藏
页码:1 / 25
页数:24
相关论文
共 50 条
  • [31] Experimental investigation of the effects of compressor types on the performance of an automobile air conditioning system using R1234yf
    Alkan, Alpaslan
    Inan, Mehmet Sait
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 58 - 66
  • [32] Experimental Performance of a Completely Passive Thermosyphon Cooling System Rejecting Heat by Natural Convection Using the Working Fluids R1234ze, R1234yf, and R134a
    Cataldo, Filippo
    Thome, John Richard
    JOURNAL OF ELECTRONIC PACKAGING, 2018, 140 (02)
  • [33] AUTOMOTIVE AIR CONDITIONING SYSTEM WITH AN INTERNAL HEAT EXCHANGER USING R1234YF AND DIFFERENT EVAPORATION AND CONDENSATION TEMPERATURES
    Direk, Mehmet
    Kelesoglu, Alper
    THERMAL SCIENCE, 2019, 23 (02): : 1115 - 1125
  • [34] Performance Evaluation of Centrifugal Refrigeration Compressor Using R1234yf and R1234ze(E) as Drop-In Replacements for R134a Refrigerant
    Yi, Kexin
    Zhao, Yuanyang
    Liu, Guangbin
    Yang, Qichao
    Yu, Guoxin
    Li, Liansheng
    ENERGIES, 2022, 15 (07)
  • [35] Experimental investigation on combustion characteristics of flammable refrigerant R290/R1234yf leakage from heat pump system for electric vehicles
    Li, Kang
    Wang, Jingwu
    Luo, Shuxian
    Wang, Zhenzhen
    Zhou, Xuejin
    Fang, Jun
    Su, Lin
    Tu, Ran
    ROYAL SOCIETY OPEN SCIENCE, 2020, 7 (04):
  • [36] Performance comparison of two absorption-compression hybrid refrigeration systems using R1234yf/ionic liquid as working pair
    Liu, Xiangyang
    Ye, Zheng
    Bai, Lihang
    He, Maogang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 181 : 319 - 330
  • [37] Performance comparison of a mobile air conditioning system using an orifice tube as an expansion device for R1234yf and R134a
    Gungor, Umut
    Hosoz, Murat
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (06) : 588 - 598
  • [38] System performance of R-1234yf refrigerant in air-conditioning and heat pump system - An overview of current status
    Wang, Chi-Chuan
    APPLIED THERMAL ENGINEERING, 2014, 73 (02) : 1412 - 1420
  • [39] Theoretical energy performance evaluation of different single stage vapour compression refrigeration configurations using R1234yf and R1234ze(E) as working fluids
    Moles, Francisco
    Navarro-Esbri, Joaquin
    Peris, Bernardo
    Mota-Babiloni, Adrian
    Barragan-Cervera, Angel
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 44 : 141 - 150
  • [40] Theoretical energy performance evaluation of different single stage vapour compression refrigeration configurations using R1234yf and R1234ze(E) as working fluids
    Molés, Francisco
    Navarro-Esbrí, Joaquín
    Peris, Bernardo
    Mota-Babiloni, Adrián
    Barragán-Cervera, Ángel
    International Journal of Refrigeration, 2014, 44 : 141 - 150