Experimental Testing of a Water-to-Water Heat Pump with and without IHX by Using Refrigerants R1234yf and R1234ze(E)

被引:3
|
作者
Bosnjakovic, Mladen [1 ]
Santa, Robert [2 ]
Katinic, Marko [3 ]
机构
[1] Univ Slavonski Brod, Techn Dept, Trg Ivane Brlic Mazuranic 2, Slavonski Brod 35000, Croatia
[2] Univ Dunaujvaros, Inst Engn Sci, Dept Mech Engn & Mat Sci, Tancs Mihaly 1-A, H-2400 Dunaujvaros, Hungary
[3] Univ Slavonski Brod, Mech Engn Fac, Trg Ivane Brlic Mazuranic 2, Slavonski Brod 35000, Croatia
关键词
heat pump; R1234ze(E); R1234yf; internal heat exchanger; COP; ENERGY PERFORMANCE EVALUATION; DROP-IN REPLACEMENT; EXCHANGER; R134A; SYSTEM; ALTERNATIVES;
D O I
10.3390/su15118625
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of heat pumps is increasing worldwide, and knowledge of their properties is becoming more and more important. Although numerous tests regarding heat pumps have been performed, due to the large number of influencing variables, the entire range of input parameters is not covered, and there is no overall picture regarding the range of the coefficient of performance (COP) of heat pumps and their output parameters. This study extends existing research and provides a much more detailed comparison of results for the application of R1234yf and R1234ze(E) refrigerants, including the pressure drop across the evaporator, condenser, and internal heat exchanger (IHX). The appropriate mathematical model for the selected components was defined and verified experimentally. A total of 60 series of measurements were performed at different evaporating and condensing temperatures. The deviation of the numerical simulation results from the experimentally determined results was up to 7.4% for cooling capacity, 8.1% for heating capacity, 7.2% for COP and 6.8% for compressor energy consumption. This study shows that COP increases from 4.77% to 10.73% for R1234ze(E) compared to R1234yf. The use of an IHX in the thermal cycle further increases COP for both refrigerants between 2.61% and 4.99%.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] R1234yf and R1234ze(E) as low-GWP refrigerants for residential heat pump water heaters
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 348 - 365
  • [2] Experimental analysis of the use of R1234yf and R1234ze(E) as drop-in alternatives of R134a in a water-to-water heat pump
    Maria Colombo, Luigi Pietro
    Lucchini, Andrea
    Molinaroli, Luca
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 18 - 27
  • [3] First experimental results of the use of R1234yf and R1234ze(E) as drop-in substitutes for R134a in a water-to-water heat pump
    Molinaroli, L.
    Lucchini, A.
    Colombo, L. P. M.
    Bocchinfuso, F.
    37TH UIT HEAT TRANSFER CONFERENCE, 2020, 1599
  • [4] Measurements of Surface Tension of R1234yf and R1234ze(E)
    Zhao, Xiaoming
    Duan, Wenhao
    Zeng, Xiaoyang
    Liu, Yu
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2018, 63 (01): : 21 - 26
  • [5] Evaporation of R1234yf, R1234ze(E) and R1234ze(Z) on Cu surface: A molecular dynamics study
    Deng, Xinxin
    Xiao, Yitian
    Li, Qibin
    He, Chao
    Wang, Shukun
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 344
  • [6] Experimental and Numerical Studies on an Automobile Air Conditioning System With the Refrigerants R134a, R1234yf, and R1234ze(E)
    Gurudatt, H. M.
    Narasimham, G. S. V. L.
    Sadashive Gowda, B.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)
  • [7] R1234yf及R1234ze(E)研究进展概述
    牛永明
    刘军
    周永
    林恩新
    制冷与空调, 2015, (11) : 82 - 91
  • [8] A Regressive Model for Periodic Dynamic Instabilities during Condensation of R1234yf and R1234ze Refrigerants
    Kuczynski, Waldemar
    Kruzel, Marcin
    Chliszcz, Katarzyna
    ENERGIES, 2022, 15 (06)
  • [9] Impact of oil presence on the evaporator enthalpy working with R1234ze(E) and R1234yf
    Sun, Yanjun
    Wei, Qiming
    Wang, Jian
    Wang, Xiaopo
    He, Maogang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 129 : 153 - 162
  • [10] Retrofitting an air-conditioning device to utilize R1234yf and R1234ze(E) refrigerants as alternatives to R22
    Oruc, Vedat
    Devecioglu, Atilla G.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (04)