Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability

被引:78
|
作者
Mueller, Maya
Dahmen, Gerlinde
Poerksen, Erk
Geerling, Gerd
Laqua, Horst
Ziegler, Andreas
Hoerauf, Hans
机构
[1] Univ Eye Clin, D-23538 Lubeck, Germany
[2] Inst Med Biometry & Stat, Lubeck, Germany
[3] Eye Clin, Kiel, Germany
[4] Univ Wurzburg, Eye Clin, Wurzburg, Germany
来源
关键词
D O I
10.1016/j.jcrs.2006.07.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width. SETTING: University Eye Clinic, Lubeck, Germany. METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application. RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/-5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 mu m for observer A and 317 +/- 60 mu m for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 mu m, the LOA from -27.20 to 22.40 mu m, and the estimated ICC 0.96. Using I instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 mu m for the opening width. CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 50 条
  • [31] Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography
    Fu Jing
    Li Shu-ning
    Wang Xiao-zhen
    Wu Ge-wei
    Mu Da-peng
    Wang Jian
    Wang Ning-li
    CHINESE MEDICAL JOURNAL, 2010, 123 (02) : 203 - 207
  • [32] Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography
    FU Jing LI Shuning WANG Xiaozhen WU Gewei MU Dapeng WANG Jian and WANG Ningli Beijing Tongren Eye Center Beijing Tongren Hospital Capital Medical University
    Beijing Ophthalmology and Visual Science Key Lab Beijing China Department of Ophthalmology Beijing Shijingshan Hospital Beijing China Department of Ophthalmology Beijing Tiantan Hospital Capital Medical University Beijing China
    中华医学杂志(英文版), 2010, (02) : 203 - 207
  • [33] Effect of Body Position on Anterior Chamber Angle Dimensions Assessed by Anterior Segment Optical Coherence Tomography
    Penteado, Rafaella
    Xu, Benjamin
    Yang, Diya
    Proudfoot, James
    Susanna, Remo
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [34] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258
  • [35] Evaluation of Scanning Protocols for Imaging the Anterior Chamber Angle With Anterior Segment-Optical Coherence Tomography
    Khor, Wei-Boon
    Sakata, Lisandro M.
    Friedman, David S.
    Narayanaswamy, Arun
    Lavanya, Raghavan
    Perera, Shamira A.
    Aung, Tin
    JOURNAL OF GLAUCOMA, 2010, 19 (06) : 365 - 368
  • [36] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [37] Repeatability and Reproducibility of Anterior Chamber Angle Measurement with Swept-Source Optical Coherence Tomography in Patients with Primary Angle Closure Suspect
    Zhao, Tong
    Zhao, Mengya
    Xie, Qinghong
    Fong, Christopher W.
    Chen, Jeremy
    Liu, Yingna
    Feng, Hui
    Li, Shuning
    Arnold, Benjamin F.
    Aung, Tin
    He, Mingguang
    Oatts, Julius T.
    Han, Ying
    CURRENT EYE RESEARCH, 2021, 46 (12) : 1853 - 1860
  • [38] Anterior Chamber Angle Morphometry Measurement Changes to Ambient Illumination Scaling in Visante Time Domain Optical Coherence Tomography
    Marion, Kenneth M.
    Dastiridou, Anna
    Niemeyer, Moritz
    Francis, Brian A.
    Sadda, Srinivas R.
    Chopra, Vikas
    CURRENT EYE RESEARCH, 2017, 42 (03) : 386 - 393
  • [39] Interobserver Agreement of Anterior Chamber Angle Measurements with Optical Coherence Tomography in Older Adults from Urban Areas of Parintins, Brazilian Amazon Region
    Berezovsky, Adriana
    Cavascan, Nivea Nunes
    Furtado, Joao M.
    Munoz, Sergio
    Cohen, Marcos Jacob
    Watanabe, Sung Eun Song
    Ferraz, Alberto Nunes
    Cohen, Jacob Moyses
    Belfort, Rubens, Jr.
    Salomao, Solange Rios
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [40] Anterior Chamber Cell Grading by Optical Coherence Tomography
    Li, Yan
    Lowder, Careen
    Zhang, Xinbo
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 258 - 265