Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability

被引:78
|
作者
Mueller, Maya
Dahmen, Gerlinde
Poerksen, Erk
Geerling, Gerd
Laqua, Horst
Ziegler, Andreas
Hoerauf, Hans
机构
[1] Univ Eye Clin, D-23538 Lubeck, Germany
[2] Inst Med Biometry & Stat, Lubeck, Germany
[3] Eye Clin, Kiel, Germany
[4] Univ Wurzburg, Eye Clin, Wurzburg, Germany
来源
关键词
D O I
10.1016/j.jcrs.2006.07.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width. SETTING: University Eye Clinic, Lubeck, Germany. METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application. RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/-5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 mu m for observer A and 317 +/- 60 mu m for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 mu m, the LOA from -27.20 to 22.40 mu m, and the estimated ICC 0.96. Using I instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 mu m for the opening width. CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 50 条
  • [21] Real-time optical coherence tomography of the anterior chamber angle.
    Radhakrishnan, S
    Reeves, D
    Lass, JH
    Szczotka, LB
    Westphal, V
    Roth, JE
    Izatt, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S791 - S791
  • [22] Anterior Chamber Angle Evaluation with Fourier-Domain Optical Coherence Tomography
    Bald, Matthew
    Li, Yan
    Huang, David
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [23] Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography
    Kim, Dong Y.
    Sung, Kyung R.
    Kang, Sung Y.
    Cho, Jung W.
    Lee, Kyoung S.
    Park, Seong B.
    Kim, Soon T.
    Kook, Michael S.
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 435 - 441
  • [24] Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
    Dai, Yingying
    Zhang, Shaodan
    Shen, Meixiao
    Zhou, Yuheng
    Wang, Mengyi
    Ye, Jie
    Zhu, Dexi
    EYE AND VISION, 2020, 7 (01)
  • [25] Assessment of the Anterior Chamber Angle in Patients with Nanophthalmos: An Anterior Segment Optical Coherence Tomography Study
    Kara, Necip
    Baz, Okkes
    Altinkaynak, Hasan
    Altan, Cigdem
    Demirok, Ahmet
    CURRENT EYE RESEARCH, 2013, 38 (05) : 563 - 568
  • [26] Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
    Yingying Dai
    Shaodan Zhang
    Meixiao Shen
    Yuheng Zhou
    Mengyi Wang
    Jie Ye
    Dexi Zhu
    Eye and Vision, 7
  • [27] Anterior segment optical coherence tomography measurement of anterior chamber depth and angle changes after phacoemulsification and intralocular lens implantation
    Kucumen, Raciha Beril
    Yenerel, Nursal Melda
    Gorgun, Ebru
    Kulacoglu, Destan Nil
    Dinc, Umut Asli
    Alimgil, Murat Levent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10): : 1694 - 1698
  • [28] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [29] Characteristics and variability of iridocorneal angle: an anterior segment optical coherence tomography study
    Meriem, Ouederni
    Fehmy, Nafaa
    Maamouri, Rym
    Hela, Sassi
    Mrad, Insaf
    Monia, Cheour
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [30] Reproducibility of Anterior Chamber Angle Measurements With Anterior Segment Coherence Tomography
    De Brabander, J.
    Tan, A. N.
    Berendschot, T. T. J. M.
    Sauren, L. D. C.
    Nekeman, D.
    Passos, V. Lima
    Webers, C. A. B.
    Beckers, H. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)