Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability

被引:78
|
作者
Mueller, Maya
Dahmen, Gerlinde
Poerksen, Erk
Geerling, Gerd
Laqua, Horst
Ziegler, Andreas
Hoerauf, Hans
机构
[1] Univ Eye Clin, D-23538 Lubeck, Germany
[2] Inst Med Biometry & Stat, Lubeck, Germany
[3] Eye Clin, Kiel, Germany
[4] Univ Wurzburg, Eye Clin, Wurzburg, Germany
来源
关键词
D O I
10.1016/j.jcrs.2006.07.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width. SETTING: University Eye Clinic, Lubeck, Germany. METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application. RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/-5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 mu m for observer A and 317 +/- 60 mu m for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 mu m, the LOA from -27.20 to 22.40 mu m, and the estimated ICC 0.96. Using I instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 mu m for the opening width. CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 50 条
  • [41] Imaging of the anterior eye chamber with optical coherence tomography
    Wirbelauer, C
    Gochmann, R
    Pham, DT
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2005, 222 (11) : 856 - 862
  • [42] Objective measurement of anterior chamber cells in children with uveitis using anterior segment optical coherence tomography
    Tsui, Edmund
    Chen, Judy L.
    Jackson, Nicholas J.
    Leyva, Omar
    Rasheed, Haroon A.
    Baghdasaryan, Elmira
    Fung, Simon
    McCurdy, Deborah K.
    Sadda, Srinivas R.
    Holland, Gary N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [43] Effect of Body Posture on Anterior Chamber Angle in Healthy Subjects: an Anterior Segment Optical Coherence Tomography Study
    Park, Ji-Hye
    Yoo, Chungkwon
    Yeon, Dong-yun
    Kim, Yong Yeon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [44] Anterior chamber angle evaluation with ultrasound biomicroscopy and optical coherence tomography in eyes implanted with a Crystalens
    Efstathios T. Detorakis
    Alexandra Karavitaki
    Nela Stojanovic
    George Kontadakis
    Ioannis G. Pallikaris
    International Ophthalmology, 2014, 34 : 781 - 786
  • [45] Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements
    Pan, Xiaojing
    Maram, Jyotsna
    Nittala, Muneeswar G.
    Francis, Brian A.
    Chopra, Vikas
    Sadda, Srinivas R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (07) : 1475 - 1481
  • [46] A study of mydriatic effect on intraocular pressure and anterior chamber angle morphology by anterior segment optical coherence tomography
    Prabhakar, Srinivasapuram Krishnacharya
    Hiremath, Meghana
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (02) : 93 - 99
  • [47] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    Eye, 2010, 24 : 578 - 587
  • [48] Comparison of Different Modes in Optical Coherence Tomography and Ultrasound Biomicroscopy in Anterior Chamber Angle Assessment
    Wang, Dandan
    Pekmezci, Melike
    Basham, Ryan P.
    He, Mingguang
    Seider, Michael I.
    Lin, Shan C.
    JOURNAL OF GLAUCOMA, 2009, 18 (06) : 472 - 478
  • [49] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    EYE, 2010, 24 (04) : 578 - 587
  • [50] Anterior chamber angle evaluation with ultrasound biomicroscopy and optical coherence tomography in eyes implanted with a Crystalens
    Detorakis, Efstathios T.
    Karavitaki, Alexandra
    Stojanovic, Nela
    Kontadakis, George
    Pallikaris, Ioannis G.
    INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (04) : 781 - 786