Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography

被引:6
|
作者
Fu Jing [1 ]
Li Shu-ning [1 ]
Wang Xiao-zhen [1 ]
Wu Ge-wei [2 ]
Mu Da-peng [1 ]
Wang Jian [3 ]
Wang Ning-li [1 ]
机构
[1] Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
[2] Beijing Shijingshan Hosp, Dept Ophthalmol, Beijing 100038, Peoples R China
[3] Capital Med Univ, Dept Ophthalmol, Beijing Tiantan Hosp, Beijing 100050, Peoples R China
关键词
rotating scheimpflug camera; anterior segment optical coherence tomography; anterior chamber volume; CORNEAL THICKNESS MEASUREMENT; ACCOMMODATION; REPEATABILITY; DIMENSIONS; ULTRASOUND; PENTACAM;
D O I
10.3760/cma.j.issn.0366-6999.2010.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Measurement of anterior segment parameters plays an important role in diagnosis and treatment of glaucoma. The objective of this study was to evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements with rotating scheimpflug camera (RSC) and to examine agreement with anterior segment optical coherence tomography (AS-OCT). Methods Thirty nine healthy normal subjects were recruited from the Eye Center of Tongren Hospital. ACV was measured using RSC and AS-OCT in a randomly selected eye for each subject. For RSC measurements, both automatic and manual ACV measurements and 2 independent operators' ACV measurements were obtained. All subjects were invited for 3 visits within a week to evaluate repeatability and reproducibility of ACV measurement by RSC. Agreement was evaluated between RSC and AS-OCT. Results Good repeatability and reproducibility were found for both automatic and manual ACV measurements obtained by RSC. For intrasession repeatability, coefficient of variation (CVw) and intraclass correlation coefficient (ICC) values for automatic were 3.52% and 0.98; the values for manual were 3.44% and 0.97, respectively. For intersession reproducibility, the respective CVw and ICC values were 3.96% and 0.96. Good agreement was also found in 2 operators for both automatic and manual ACV measurements; nevertheless, poor agreement was found between RSC and AS-OCT (95% confidence interval (CI) for agreement of automatic RSC measurement versus AS-OCT were -96.3 to 72.8 mu l and 95% Cl for agreement of manual RSC measurement versus AS-OCT were between -41.7 to 10.1 mu l). Conclusions Both RSC automatic and manual ACV measurements showed good repeatability and reproducibility, and showed comparable agreement between 2 independent operators, but poor agreement was found between RSC and AS-OCT Chin Med J 2010;123(2):203-207
引用
收藏
页码:203 / 207
页数:5
相关论文
共 50 条
  • [1] Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography
    FU Jing LI Shuning WANG Xiaozhen WU Gewei MU Dapeng WANG Jian and WANG Ningli Beijing Tongren Eye Center Beijing Tongren Hospital Capital Medical University
    Beijing Ophthalmology and Visual Science Key Lab Beijing China Department of Ophthalmology Beijing Shijingshan Hospital Beijing China Department of Ophthalmology Beijing Tiantan Hospital Capital Medical University Beijing China
    中华医学杂志(英文版), 2010, (02) : 203 - 207
  • [2] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [3] Comparison of Anterior Segment Measurements between Scheimpflug Camera and New Module of Optical Coherence Tomography
    Kim, Jae Min
    Kang, Min Seok
    Jin, Kyung Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (07): : 613 - 621
  • [4] Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles
    D S Grewal
    G S Brar
    R Jain
    S P S Grewal
    Eye, 2011, 25 : 603 - 611
  • [5] Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles
    Grewal, D. S.
    Brar, G. S.
    Jain, R.
    Grewal, S. P. S.
    EYE, 2011, 25 (05) : 603 - 611
  • [6] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [7] Anterior segment parameters of rabbits with rotating Scheimpflug camera
    Yuksel, Harun
    Turkcu, Fatih M.
    Ari, Seyhmus
    Cinar, Yasin
    Cingu, Abdullah K.
    Sahin, Muhammed
    Sahin, Alparslan
    Ozkurt, Zeynep
    Caca, Ihsan
    VETERINARY OPHTHALMOLOGY, 2015, 18 (03) : 210 - 213
  • [8] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [9] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [10] Grading Anterior Chamber Inflammation with Anterior Segment Optical Coherence Tomography: An Overview
    Maring, Morgan
    Saraf, Steven S.
    Blazes, Marian
    Sharma, Sumit
    Srivastava, Sunil
    Pepple, Kathryn L.
    Lee, Cecilia S.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2022, 30 (02) : 357 - 363