Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

被引:5
|
作者
Martins, M. C. [1 ]
Cordeiro, T. P. V. [1 ]
Silva, A. X. [1 ]
Souza-Santos, D. [2 ]
Queiroz-Filho, P. P. [2 ]
Hunt, J. G. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, BR-21941914 Rio De Janeiro, Brazil
[2] Inst Radioprotecao & Dosimetria, Div Dosimetria, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
Voxel phantom; ICRP110; Geant4; RADIATION PROTECTION;
D O I
10.1016/j.radphyschem.2013.04.030
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The reference adult male voxel phantom recommended by International Commission on Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 was used to calculate Dose Conversion Coefficients (DCCs) expressed as dose deposited in organs per air kerma for photons, electrons and neutrons in the Annals of the ICRP. In this work the AP and PA irradiation geometries of the ICRP male phantom were simulated for the purpose of benchmarking the Geant4 code. Monoenergetic photons were simulated between 15 key and 10 MeV and the results were compared with ICRP 110, the VMC Monte Carlo code and the literature data available, presenting a good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [31] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [32] Dose enhancement of nanogold for prostate radiation: Monte Carlo simulation using the ICRP voxel computational male phantom
    Al-Saleh, Wafa M.
    Almatani, Turki
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2024, 18 (01):
  • [33] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [34] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [35] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Rahman, Ziaur
    Rehman, Shakeel Ur
    Arshed, Waheed
    Mirza, Nasir M.
    Rashid, Abdul
    Zeb, Jahan
    CHINESE PHYSICS C, 2012, 36 (11) : 1150 - 1156
  • [36] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [37] Implementation of geant4 application for tomography emission Monte Carlo Code in the calculation of dose distribution in external radiation therapy
    Dehghan, A. B. Yeke
    Mostaar, A.
    Azadeh, P.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (04):
  • [38] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, 36 (11) : 1150 - 1156
  • [39] Ambient Dose Equivalent Per Therapeutic Dose for 250 Mev Proton Interactions in Tissues using GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S704 - S705
  • [40] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223