Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

被引:5
|
作者
Martins, M. C. [1 ]
Cordeiro, T. P. V. [1 ]
Silva, A. X. [1 ]
Souza-Santos, D. [2 ]
Queiroz-Filho, P. P. [2 ]
Hunt, J. G. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, BR-21941914 Rio De Janeiro, Brazil
[2] Inst Radioprotecao & Dosimetria, Div Dosimetria, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
Voxel phantom; ICRP110; Geant4; RADIATION PROTECTION;
D O I
10.1016/j.radphyschem.2013.04.030
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The reference adult male voxel phantom recommended by International Commission on Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 was used to calculate Dose Conversion Coefficients (DCCs) expressed as dose deposited in organs per air kerma for photons, electrons and neutrons in the Annals of the ICRP. In this work the AP and PA irradiation geometries of the ICRP male phantom were simulated for the purpose of benchmarking the Geant4 code. Monoenergetic photons were simulated between 15 key and 10 MeV and the results were compared with ICRP 110, the VMC Monte Carlo code and the literature data available, presenting a good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [41] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [42] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [43] Incorporation of the Goudsmit-Saunderson electron transport theory in the Geant4 Monte Carlo code
    Kadri, O.
    Ivanchenko, V.
    Gharbi, F.
    Trabelsi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (23-24): : 3624 - 3632
  • [44] Monte Carlo GEANT4 Simulation of the Deposited Doses by Different Types of Particles Estimated in a Water Phantom
    Elmoujaddidi, Chaimaa
    Ghazi, Ismail
    Chakir, Hamid
    Sebihi, Rajaa
    Kartouni, Abdelkrim
    Krim, Mustapha
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2022, 19 (06) : 685 - 692
  • [45] Monte Carlo GEANT4 Simulation of the Deposited Doses by Different Types of Particles Estimated in a Water Phantom
    Ismail Chaimaa Elmoujaddidi
    Hamid Ghazi
    Rajaa Chakir
    Abdelkrim Sebihi
    Mustapha Kartouni
    Physics of Particles and Nuclei Letters, 2022, 19 : 685 - 692
  • [46] An EGS4 based Monte Carlo code for the calculation of organ equivalent dose to a modified Yale voxel phantom
    Kramer, R
    Vieira, JW
    Lima, FRA
    Fuelle, D
    CELLULAR AND MOLECULAR BIOLOGY, 2002, 48 (05) : 465 - 473
  • [47] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [48] Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions
    Cirrone, GAP
    Cuttone, G
    Pia, MG
    Guatelli, S
    Lo Nigro, S
    Sabini, MG
    Lo Nigro, S
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [49] Implementation of the reverse/adjoint Monte Carlo method into Geant4
    Desorgher, L.
    Lei, F.
    Santin, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 247 - 257
  • [50] Cancer risk estimation in Digital Breast Tomosynthesis using GEANT4 Monte Carlo simulations and voxel phantoms
    Ferreira, P.
    Baptista, M.
    Di Maria, S.
    Vaz, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 717 - 723