Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

被引:5
|
作者
Martins, M. C. [1 ]
Cordeiro, T. P. V. [1 ]
Silva, A. X. [1 ]
Souza-Santos, D. [2 ]
Queiroz-Filho, P. P. [2 ]
Hunt, J. G. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, BR-21941914 Rio De Janeiro, Brazil
[2] Inst Radioprotecao & Dosimetria, Div Dosimetria, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
Voxel phantom; ICRP110; Geant4; RADIATION PROTECTION;
D O I
10.1016/j.radphyschem.2013.04.030
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The reference adult male voxel phantom recommended by International Commission on Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 was used to calculate Dose Conversion Coefficients (DCCs) expressed as dose deposited in organs per air kerma for photons, electrons and neutrons in the Annals of the ICRP. In this work the AP and PA irradiation geometries of the ICRP male phantom were simulated for the purpose of benchmarking the Geant4 code. Monoenergetic photons were simulated between 15 key and 10 MeV and the results were compared with ICRP 110, the VMC Monte Carlo code and the literature data available, presenting a good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [21] GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
    Jahnke, Lennart
    Fleckenstein, Jens
    Wenz, Frederik
    Hesser, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1217 - 1229
  • [22] The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code
    Zhang, Bintuan
    Dang, Bingrong
    Wang, Zhuanzi
    Wei, Wei
    Li, Wenjian
    RADIATION PROTECTION DOSIMETRY, 2013, 156 (04) : 514 - 517
  • [23] Verification and Validation of the Geant4 Monte Carlo Code Toolkit for DEMO TBR Evaluations
    Nunnenmann, Elena
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2020, 161
  • [24] Monte Carlo studies of the Tunisian gamma irradiation facility using GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    Mannai, K
    Trabelsi, A
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (02) : 170 - 177
  • [25] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [26] Optimization of the Monte Carlo simulation model of NaI(Tl) detector by Geant4 code
    Hoang Duc Tam
    Nguyen Thi Hai Yen
    Le Bao Tran
    Huynh Dinh Chuong
    Tran Thien Thanh
    APPLIED RADIATION AND ISOTOPES, 2017, 130 : 75 - 79
  • [27] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [28] Voxel-based dose calculation of radionuclide imaging and therapy for preclinical studies using GEANT4 Monte Carlo simulation
    Liu, H.
    Geng, C.
    Tang, X.
    Tang, L.
    Li, X.
    Xu, P.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 317 - 322
  • [29] Modelling of MR-guided radiotherapy system on Monte Carlo code GEANT4
    Okamoto, H.
    Nishioka, S.
    Iijima, K.
    Sakasai, T.
    Miura, Y.
    Wakita, A.
    Nakamura, S.
    Shibata, Y.
    Abe, Y.
    Igaki, H.
    Itami, J.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S947 - S947
  • [30] RADIOTHERAPY MONTE CARLO DOSIMETRY USING GATE/GEANT4: VALIDATION STUDY IN ANTHROPOMORPHIC PHANTOM
    Perrot, Y.
    Breton, V.
    Donnarieix, D.
    Maigne, L.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S491 - S492