摘要
The skin tissue-equivalent slab reported in the International Commission on Radiological Protection (ICRP) Publication 116 to calculate the localised skin dose conversion coefficients (LSDCCs) was adopted into the Monte Carlo transport code Geant4. The Geant4 code was then utilised for computation of LSDCCs due to a circular parallel beam of monoenergetic electrons, protons and alpha particles 10 MeV. The computed LSDCCs for both electrons and alpha particles are found to be in good agreement with the results using the MCNPX code of ICRP 116 data. The present work thus validates the LSDCC values for both electrons and alpha particles using the Geant4 code.
引用
收藏
页码:514 / 517
页数:4
相关论文
共 41 条
  • [1] Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code
    Paganini, S
    Vilela, E
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 818 - 820
  • [2] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [3] Study on GEANT4 Code Applications to Dose Calculation Using Imaging Data
    Lee, Jeong Ok
    Kang, Jeong Ku
    Kim, Jhin Kee
    Kwon, Hyeong Cheol
    Kim, Jung Soo
    Kim, Bu Gil
    Jeong, Dong Hyeok
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 195 - 198
  • [4] Study on GEANT4 code applications to dose calculation using imaging data
    Jeong Ok Lee
    Jeong Ku Kang
    Jhin Kee Kim
    Hyeong Cheol Kwon
    Jung Soo Kim
    Bu Gil Kim
    Dong Hyeok Jeong
    Journal of the Korean Physical Society, 2015, 67 : 195 - 198
  • [5] Calculation of the initial DNA damage induced by alpha particles in comparison with protons and electrons using Geant4-DNA
    Moeini, Hossein
    Mokari, Mojtaba
    Alamatsaz, Mohammad Hassan
    Taleei, Reza
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2020, 96 (06) : 767 - 778
  • [6] Stopping power and ranges of electrons, protons and alpha particles in liquid water using the Geant4-DNA package
    Francis, Z.
    Incerti, S.
    Karamitros, M.
    Tran, H. N.
    Villagrasa, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (20): : 2307 - 2311
  • [7] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [8] A Geant4 Simulation of the Depth Dose Percentage in Brain Tumors Treatments Using Protons and Carbon Ions
    Diaz M., Jose A.
    Torres, D. A.
    LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2016, 1753
  • [9] Fluence-to-dose conversion coefficients for neutrons and protons calculated using the PHITS code and ICRP/ICRU adult reference computational phantoms
    Sato, Tatsuhiko
    Endo, Akira
    Zankl, Maria
    Petoussi-Henss, Nina
    Niita, Koji
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07): : 1997 - 2014
  • [10] Calculation and benchmark of fluence-to-local skin equivalent dose coefficients for neutrons with FLUKA, MCNP, and GEANT4 Monte-Carlo codes
    Frosio, Thomas
    Bertreix, Philippe
    Menaa, Nabil
    Thomas, Samuel
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (03) : 564 - 578