The local skin dose conversion coefficients of electrons, protons and alpha particles calculated using the Geant4 code

被引:3
|
作者
Zhang, Bintuan [1 ,2 ]
Dang, Bingrong [1 ]
Wang, Zhuanzi [1 ]
Wei, Wei [1 ]
Li, Wenjian [1 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
PHYSICS; MICRODOSIMETRY; SIMULATION; MODELS;
D O I
10.1093/rpd/nct102
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The skin tissue-equivalent slab reported in the International Commission on Radiological Protection (ICRP) Publication 116 to calculate the localised skin dose conversion coefficients (LSDCCs) was adopted into the Monte Carlo transport code Geant4. The Geant4 code was then utilised for computation of LSDCCs due to a circular parallel beam of monoenergetic electrons, protons and alpha particles 10 MeV. The computed LSDCCs for both electrons and alpha particles are found to be in good agreement with the results using the MCNPX code of ICRP 116 data. The present work thus validates the LSDCC values for both electrons and alpha particles using the Geant4 code.
引用
收藏
页码:514 / 517
页数:4
相关论文
共 41 条
  • [31] SELECTED ORGAN DOSE CONVERSION COEFFICIENTS FOR EXTERNAL PHOTONS CALCULATED USING ICRP ADULT VOXEL PHANTOMS AND MONTE CARLO CODE FLUKA
    Patni, H. K.
    Nadar, M. Y.
    Akar, D. K.
    Bhati, S.
    Sarkar, P. K.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 406 - 416
  • [32] Fluence-to-dose conversion coefficients for heavy ions calculated using the PHITS code and the ICRP/ICRU adult reference computational phantoms
    Sato, Tatsuhiko
    Endo, Akira
    Niita, Koji
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (08): : 2235 - 2246
  • [33] Determination of Dose Distributions by Monte-Carlo Simulation of 6 MV Photon Beam of Varian VitalBeam Accelerator Using Geant4 Multithreaded Code
    Chiuyo, Julius
    Lugendo, Innocent
    Muhogora, Wilbroad
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (02) : 181 - 188
  • [34] MONTE CARLO DOSE MODELLING OF EMBEDDED BETA/ GAMMA EMISSIONS FROM DART ALPHA-EMITTERS BRACHYTHERAPY SEEDS USING GEANT4
    Mondor, Julien
    Kamio, Yuji
    Cheve, Patrick
    Carrier, Jean-Francois
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S87 - S87
  • [35] A comparison of the measured responses of a tissue-equivalent proportional counter to high energy heavy (HZE) particles and those simulated using the Geant4 Monte Carlo code
    Taddei, Phillip J.
    Zhao, Zhongxiang
    Borak, Thomas B.
    RADIATION MEASUREMENTS, 2008, 43 (9-10) : 1498 - 1505
  • [36] Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code (vol 42, pg 6234, 2015)
    Guan, Fada
    Peeler, Christopher
    Bronk, Lawrence
    Geng, Changran
    Taleei, Reza
    Randeniya, Sharmalee
    Ge, Shuaiping
    Mirkovic, Dragan
    Grosshans, David
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2018, 45 (03) : 1302 - 1302
  • [37] Calculation of DNA strand breaks due to direct and indirect effects of Auger electrons from incorporated 123I and 125I radionuclides using the Geant4 computer code
    Raisali, Gholamreza
    Mirzakhanian, Lalageh
    Masoudi, Seyed Farhad
    Semsarha, Farid
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2013, 89 (01) : 57 - 64
  • [38] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147
  • [39] FLUENCE TO ABSORBED DOSE, EFFECTIVE DOSE AND GRAY EQUIVALENT CONVERSION COEFFICIENTS FOR IRON NUCLEI FROM 10 MeV TO 1 TeV, CALCULATED USING MONTE CARLO RADIATION TRANSPORT CODE MCNPX 2.7.A
    Copeland, Kyle
    Parker, Donald E.
    Friedberg, Wallace
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (04) : 353 - 362
  • [40] HELIONS AT ENERGIES OF 10 MEV TO 1 TEV: CONVERSION COEFFICIENTS FOR FLUENCE-TO-ABSORBED DOSE, EQUIVALENT DOSE, EFFECTIVE DOSE AND GRAY EQUIVALENT, CALCULATED USING MONTE CARLO RADIATION TRANSPORT CODE MCNPX 2.7.C
    Copeland, Kyle
    Parker, Donald E.
    Friedberg, Wallace