Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code

被引:5
|
作者
Martins, M. C. [1 ]
Cordeiro, T. P. V. [1 ]
Silva, A. X. [1 ]
Souza-Santos, D. [2 ]
Queiroz-Filho, P. P. [2 ]
Hunt, J. G. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Ctr Tecnol, BR-21941914 Rio De Janeiro, Brazil
[2] Inst Radioprotecao & Dosimetria, Div Dosimetria, BR-22783127 Rio De Janeiro, RJ, Brazil
关键词
Voxel phantom; ICRP110; Geant4; RADIATION PROTECTION;
D O I
10.1016/j.radphyschem.2013.04.030
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The reference adult male voxel phantom recommended by International Commission on Radiological Protection no. 110 was implemented in the Geant4 Monte Carlo code. Geant4 was used to calculate Dose Conversion Coefficients (DCCs) expressed as dose deposited in organs per air kerma for photons, electrons and neutrons in the Annals of the ICRP. In this work the AP and PA irradiation geometries of the ICRP male phantom were simulated for the purpose of benchmarking the Geant4 code. Monoenergetic photons were simulated between 15 key and 10 MeV and the results were compared with ICRP 110, the VMC Monte Carlo code and the literature data available, presenting a good agreement. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [1] Evaluation of the fluence to dose conversion coefficients for high energy neutrons using a voxel phantom coupled with the GEANT4 code
    Paganini, S
    Vilela, E
    BRAZILIAN JOURNAL OF PHYSICS, 2005, 35 (3B) : 818 - 820
  • [2] Adaptation of the Geant4 ICRP110 Human Phantom advanced example for nuclear medicine applications to allow overlay of lesions as Geant4 parallel world objects
    Salman, Muhammad
    Large, Matthew
    Rosenfeld, Anatoly
    Guatelli, Susanna
    Malaroda, Alessandra
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [3] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [4] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [5] SELECTED ORGAN DOSE CONVERSION COEFFICIENTS FOR EXTERNAL PHOTONS CALCULATED USING ICRP ADULT VOXEL PHANTOMS AND MONTE CARLO CODE FLUKA
    Patni, H. K.
    Nadar, M. Y.
    Akar, D. K.
    Bhati, S.
    Sarkar, P. K.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 406 - 416
  • [6] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [7] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Adil Bardane
    Jaouad Tajmouaati
    Abdelmajid Maghnouj
    Moscow University Physics Bulletin, 2020, 75 : 58 - 62
  • [8] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [9] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [10] Comparison Among Homogeneous Models and a Voxel Model on Mammography: a Monte Carlo Study Using the GEANT4 code
    Cassola, Vagner F.
    Hoff, Gabriela
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2428 - +