Geant4 Monte Carlo simulations for the LPCTrap setup

被引:0
|
作者
D. Rodríguez
G. Ban
D. Durand
F. Duval
X. Fléchard
E. Liénard
F. Mauger
A. Méry
O. Naviliat-Cuncic
J. -C. Thomas
Ph. Velten
机构
[1] Universidad de Huelva,Departamento de Física Aplicada
[2] Université de Caen Basse-Normandie,LPC
[3] CNRS/IN2P3-ENSI,Caen, ENSICAEN
[4] GANIL,Departamento de Física Atómica Molecular y Nuclear
[5] CEA/DSM-CNRS/IN2P3,undefined
[6] Universidad de Granada,undefined
来源
关键词
Radio Frequency; Paul Trap; Geant4 Simulation; Geant4 Monte Carlo Simulation; Spiral Source;
D O I
暂无
中图分类号
学科分类号
摘要
The LPCTrap setup at GANIL is fully operational since 2006. The first breakthrough was the detection of 100000 coincidences between the \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta$\end{document} particles and the recoil ions from the decay of 6He+ produced by the SPIRAL source. After preparation, the decaying nuclei are confined in a transparent Paul trap which is surrounded by a \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta$\end{document} -telescope made of a double-sided silicon strip detector followed by a scintillator, and by a micro-channel plate position-sensitive detector to record in coincidence the \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta$\end{document} particles and the recoil ions. Simulations of this system are needed in order to study possible systematic effects and extract with high accuracy the \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \beta$\end{document} -\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$ \nu$\end{document} angular-correlation coefficient. A code based on Geant4 is well suited for this purpose. In this contribution the results from the simulations compared with those from the experiment will be presented and discussed.
引用
收藏
页码:397 / 400
页数:3
相关论文
共 50 条
  • [1] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    [J]. EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [2] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [3] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [4] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [5] Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations
    Szentmiklosi, Laszlo
    Belgya, Tamas
    Maroti, Boglarka
    Kis, Zoltan
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (02) : 553 - 558
  • [6] Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations
    László Szentmiklósi
    Tamás Belgya
    Boglárka Maróti
    Zoltán Kis
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 : 553 - 558
  • [7] Validating Geant4 with Monte Carlo simulations in the context of nuclear disarmament verification
    Kreutle, Manuel
    Borella, Alessandro
    Hebel, Simon
    Kirchner, Gerald
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [8] Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations
    Tacke, MB
    Szymanowski, H
    Oelfke, U
    Schulze, C
    Nuss, S
    Wehrwein, E
    Leidenberger, S
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 1125 - 1132
  • [9] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [10] PRELIMINARY STUDY OF PROTON RADIOGRAPHY IMAGING QUALITIES USING GEANT4 MONTE CARLO SIMULATIONS
    Depauw, Nicolas
    Danto, Sylvain
    Bednarz, Bryan
    Paganetti, Harald
    Fink, Yoel
    Seco, Joao
    [J]. NUCLEAR TECHNOLOGY, 2011, 175 (01) : 6 - 10