Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations

被引:14
|
作者
Tacke, MB
Szymanowski, H
Oelfke, U
Schulze, C
Nuss, S
Wehrwein, E
Leidenberger, S
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Siemens Med Solut, Oncol Care Syst, D-69123 Heidelberg, Germany
关键词
multileaf collimator; Monte Carlo; GEANT4;
D O I
10.1118/1.2181298
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the work was to investigate in advance the dosimetric properties of a new multileaf collimator (MLC) concept with the help of Monte Carlo (MC) simulations prior to the production of a prototype. The geometrical design of the MLC was implemented in the MC code GEANT4. For the simulation of a 6 MV treatment beam, an experimentally validated phase space and a virtual spatial Gaussian-shaped model placed in the origin were used. For the simulation of the geometry in GEANT4, the jaws and the two leaf packages were implemented with the help of computer-aided design data. First, transmission values for different tungsten alloys were extracted using the simulation codes GEANT4 and BEAMnrc and compared to experimental measurements. In a second step, high-resolution simulations were performed to detect the leakage at depth of maximum dose. The 20%-80% penumbra along the travel direction of the leaves was determined using 10 X 10 cm(2) fields shifted along the x- and y-axis. The simulated results were compared with measured data. The simulation of the transmission values for different tungsten alloys showed a good agreement with the experimental measurements (within 2.0%). This enabled an accurate estimation of the attenuation coefficient for the various leaf materials. Simulations with varying width of the spatial Gaussian distribution showed that the leakage and the penumbra depend very much on this parameter: for instance, for widths of 2 and 4 mm, the interleaf leakage is below 0.3% and 0.75%, respectively. The results for the leakage and the penumbra (4.7 +/- 0.5 mm) are in good agreement with the measurements. This study showed that GEANT4 is appropriate for the investigation of the dosimetric properties of a multileaf collimator. In particular, a quantification of the leakage, the penumbra, and the tongue-and-groove effect and an evaluation of the influence of the beam parameters such as the width of the Gaussian distribution was possible. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1125 / 1132
页数:8
相关论文
共 50 条
  • [1] A Comprehensive Geant4 Monte Carlo Model of Multileaf Collimator for Varian TrueBeam Linac
    Kandlakunta, P.
    Zhang, T.
    Mutic, S.
    Khan, R.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2909 - 2909
  • [2] Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
    Kandlakunta, Praneeth
    Momin, Shadab
    Sloop, Austin
    Zhang, Tiezhi
    Khan, Rao
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 1 - 12
  • [3] Dosimetric impact assessment using a general algorithm in GEANT4 simulations for a complex-shaped multileaf collimator
    Perales, A.
    Cortes-Giraldo, M. A.
    Miras, H.
    Arrans, R.
    Gallardo, M. I.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 39 - 45
  • [4] Monte Carlo simulations of the dosimetric characteristics of a new multileaf collimator
    Tacke, M
    Szymanowski, H
    Schulze, C
    Nuss, S
    Wehrwein, E
    Leidenberger, S
    Oelfke, U
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2018 - 2018
  • [5] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    [J]. EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [6] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    [J]. The European Physical Journal A, 2009, 42 : 397 - 400
  • [7] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [8] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [9] External dose assessment of NORM added consumer products using Geant4 Monte Carlo simulations
    Hassan, Halmat J.
    Hashim, S.
    Abu Hanifah, N. Z. H.
    Sanusi, M. S. M.
    Fahmi, M. R.
    Tahar, R. M.
    Bradley, D. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [10] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396