A Comprehensive Geant4 Monte Carlo Model of Multileaf Collimator for Varian TrueBeam Linac

被引:0
|
作者
Kandlakunta, P. [1 ]
Zhang, T. [1 ]
Mutic, S. [1 ]
Khan, R. [1 ]
机构
[1] Washington Univ, Sch Med, St Louis, MO USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:2909 / 2909
页数:1
相关论文
共 50 条
  • [1] Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator
    Kandlakunta, Praneeth
    Momin, Shadab
    Sloop, Austin
    Zhang, Tiezhi
    Khan, Rao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 1 - 12
  • [2] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [3] Assessment of a new multileaf collimator concept using GEANT4 Monte Carlo simulations
    Tacke, MB
    Szymanowski, H
    Oelfke, U
    Schulze, C
    Nuss, S
    Wehrwein, E
    Leidenberger, S
    MEDICAL PHYSICS, 2006, 33 (04) : 1125 - 1132
  • [4] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [5] Validation of Monte carlo Geant4 multithreading code for a 6 MV photon beam of varian linac on the grid computing
    Assalmi, Mustapha
    Diaf, El Yamani
    Mansour, Najim
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 1001 - 1010
  • [6] Monte Carlo Modeling and Simulation of the Varian TrueBeam LINAC Using Heterogeneous Computing
    Lin, H.
    Liu, T.
    Su, L.
    Shi, C.
    Tang, X.
    Adam, D.
    Bednarz, B.
    Xu, X.
    MEDICAL PHYSICS, 2017, 44 (06) : 3003 - 3003
  • [7] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [8] Analytical and Monte-Carlo (GEANT4) calculations of collimator scatter of proton beams
    Ulmer, W.
    Schaffner, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2419 - 2419
  • [9] A geometrical model for the Monte Carlo simulation of the TrueBeam linac
    Rodriguez, M.
    Sempau, J.
    Fogliata, A.
    Cozzi, L.
    Sauerwein, W.
    Brualla, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : N219 - N229
  • [10] Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the Varian TrueBeam Linac
    Lloyd, Samantha A. M.
    Gagne, Isabelle M.
    Bazalova-Carter, Magdalena
    Zavgorodni, Sergei
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (24): : 8779 - 8793