Analytical and Monte-Carlo (GEANT4) calculations of collimator scatter of proton beams

被引:0
|
作者
Ulmer, W. [1 ]
Schaffner, B. [1 ]
机构
[1] Varian Med Syst, Baden, Switzerland
关键词
D O I
10.1118/1.2760731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Collimator scatter of proton beams is being implemented in the proton dose model in ECLIPSE (Varian). Due to the energy loss and angular scatter distributions at the collimator walls (brass) the spectrum of scatter protons is rather intricate. This contribution is significant for the ‘horns’ of transverse profiles verified in the initial plateau of Bragg curves. Using an analytical integration procedure of Bethe‐Bloch equation and its application to the Molière multiple scatter model the calculated contributions are compared with measured data and Monte‐Carlo calculations (GEANT4). The production of secondary protons and radiation effects is determined by an integration of the inelastic cross‐section of the corresponding wall material over the energy. Method and Materials: Monte‐Carlo calculations have been carried out with GEANT4. Measurement data of transverse profiles and Bragg curves have been made available by the Harvard cyclotron and the proton center of MD Anderson (Houston). Results: Material properties and collimator length have an influence to the beam‐line (energy spectrum, fluence, angular distribution). Since the collimator edge act as further proton source, the distance to the water tank significantly affects the Bragg curves of small field sizes (from 0.5 × 0.5 cm2 to 2 × 2 cm2). For larger field sizes the collimator scatter leads to ‘horns’ in the transverse profiles and to a buildup effect in the initial plateau of Bragg curves. Conclusion: Monte‐Carlo and analytical calculations are in good agreement with measurement data. A practical impact is also application of proton beams to the stereotactic radiotherapy. Conflict of Interest: Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2419 / 2419
页数:1
相关论文
共 50 条
  • [1] Analysis of the physical interactions of therapeutic proton beams in water with the use of Geant4 Monte Carlo calculations
    Moravek, Zdenek
    Bogner, Ludwig
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2009, 19 (03): : 174 - 181
  • [2] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [3] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [4] Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
    Padilla-Cabal, Fatima
    Alejandro Fragoso, Jose
    Resch, Andreas Franz
    Georg, Dietmar
    Fuchs, Hermann
    [J]. MEDICAL PHYSICS, 2020, 47 (01) : 223 - 233
  • [5] Aspects of GEANT4 Monte-Carlo calculations of the BC501A neutron detector
    Patronis, N.
    Kokkoris, M.
    Giantsoudi, D.
    Perdikakis, G.
    Papadopoulos, C. T.
    Vlastou, R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (01): : 351 - 355
  • [6] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [7] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [8] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [9] Monte-Carlo Geant4 numerical simulation of experiments at 247-MeV proton microscope
    Kantsyrev, A. V.
    Skoblyakov, A. V.
    Bogdanov, A. V.
    Golubev, A. A.
    Shilkin, N. S.
    Yuriev, D. S.
    Mintsev, V. B.
    [J]. XXXII INTERNATIONAL CONFERENCE ON INTERACTION OF INTENSE ENERGY FLUXES WITH MATTER (ELBRUS 2017), 2018, 946
  • [10] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169