Analytical and Monte-Carlo (GEANT4) calculations of collimator scatter of proton beams

被引:0
|
作者
Ulmer, W. [1 ]
Schaffner, B. [1 ]
机构
[1] Varian Med Syst, Baden, Switzerland
关键词
D O I
10.1118/1.2760731
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Collimator scatter of proton beams is being implemented in the proton dose model in ECLIPSE (Varian). Due to the energy loss and angular scatter distributions at the collimator walls (brass) the spectrum of scatter protons is rather intricate. This contribution is significant for the ‘horns’ of transverse profiles verified in the initial plateau of Bragg curves. Using an analytical integration procedure of Bethe‐Bloch equation and its application to the Molière multiple scatter model the calculated contributions are compared with measured data and Monte‐Carlo calculations (GEANT4). The production of secondary protons and radiation effects is determined by an integration of the inelastic cross‐section of the corresponding wall material over the energy. Method and Materials: Monte‐Carlo calculations have been carried out with GEANT4. Measurement data of transverse profiles and Bragg curves have been made available by the Harvard cyclotron and the proton center of MD Anderson (Houston). Results: Material properties and collimator length have an influence to the beam‐line (energy spectrum, fluence, angular distribution). Since the collimator edge act as further proton source, the distance to the water tank significantly affects the Bragg curves of small field sizes (from 0.5 × 0.5 cm2 to 2 × 2 cm2). For larger field sizes the collimator scatter leads to ‘horns’ in the transverse profiles and to a buildup effect in the initial plateau of Bragg curves. Conclusion: Monte‐Carlo and analytical calculations are in good agreement with measurement data. A practical impact is also application of proton beams to the stereotactic radiotherapy. Conflict of Interest: Varian Medical Systems. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2419 / 2419
页数:1
相关论文
共 50 条
  • [21] A Geant4/TOPAS Monte Carlo System for Validating Proton Therapy Treatment Plan Calculations at Mayo Clinic
    Tseung, H. Wan Chan
    Beltran, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [22] Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions
    Cirrone, GAP
    Cuttone, G
    Pia, MG
    Guatelli, S
    Lo Nigro, S
    Sabini, MG
    Lo Nigro, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [23] Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and geant4
    Barret, O
    Carpenter, TA
    Clark, JC
    Ansorge, RE
    Fryer, TD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20): : 4823 - 4840
  • [24] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [25] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    [J]. BioMedical Engineering OnLine, 13
  • [26] Optimization of an ultra-fast silicon detector for proton and carbon beams using GEANT4 Monte Carlo toolkit
    Mashayekhi, Mohsen
    Mowlavi, Ali Asghar
    Jia, Sayyed Bijan
    Ghayoumizadeh, Hossein
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 109 - 112
  • [27] Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields
    Gholami, Somayeh
    Longo, Francesco
    Nedaie, Hassan Ali
    Berti, Alessio
    Mousavi, Mehdi
    Meigooni, Ali S.
    [J]. MEDICAL DOSIMETRY, 2018, 43 (03) : 214 - 223
  • [28] GEANT4 Monte-Carlo Simulation of Dosimetry Parameters of the Passively Scattered Beam Lines at the Proton Therapy Center in Houston
    Ding, X.
    Sahoo, N.
    Song, X.
    Zhu, X.
    Lii, M.
    Gillin, M.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    [J]. EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [30] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130