Ambient Dose Equivalent Per Therapeutic Dose for 250 Mev Proton Interactions in Tissues using GEANT4 Monte Carlo Code

被引:0
|
作者
Chen, Y. [1 ]
Ahmad, S. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK USA
关键词
D O I
10.1016/j.ijrobp.2009.07.1606
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:S704 / S705
页数:2
相关论文
共 50 条
  • [1] Neutron and Photon Fluence Distributions and Ambient Dose Equivalents for 250 MeV Proton Interactions in Tissue Using Geant4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Systematic Analysis of the Neutron Equivalent Dose in a Mevion S250 Proton Therapy Machine Using Geant4 Monte Carlo Simulation
    Tatari, N.
    Baradaran-Ghahfarokhi, M.
    Roeder, B.
    Zhao, T.
    Khan, R.
    Sobotka, L.
    Darafsheh, A.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [4] Neutron Yield and Angular Distribution From the 250 MeV Proton Interactions in Water: A Geant4 Monte Carlo Study
    Chen, Y.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [5] Development of a Full Monte Carlo Therapeutic Dose Calculation Toolkit for Halcyon Using Geant4
    Liu, R.
    Ji, Z.
    Cai, B.
    Hugo, G.
    Mutic, S.
    Zhao, T.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E742 - E742
  • [6] Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions
    Cirrone, GAP
    Cuttone, G
    Pia, MG
    Guatelli, S
    Lo Nigro, S
    Sabini, MG
    Lo Nigro, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [7] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code
    Guan, Fada
    Peeler, Christopher
    Bronk, Lawrence
    Geng, Changran
    Taleei, Reza
    Randeniya, Sharmalee
    Ge, Shuaiping
    Mirkovic, Dragan
    Grosshans, David
    Mohan, Radhe
    Titt, Uwe
    [J]. MEDICAL PHYSICS, 2015, 42 (11) : 6234 - 6247
  • [9] Energy Distributions of Particles Generated for Proton Interactions in Water: A Simulation with GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Simulated design of neutron ambient dose equivalent meter with gadolinium core plastic scintillator using Geant4 code
    Hong, B.
    Xu, Y.
    Chen, N.
    [J]. RADIATION MEASUREMENTS, 2021, 144