Simulated design of neutron ambient dose equivalent meter with gadolinium core plastic scintillator using Geant4 code

被引:1
|
作者
Hong, B. [1 ]
Xu, Y. [2 ]
Chen, N. [2 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Anhui Med Univ, Teaching & Res Sect Nucl Med, Hefei 230032, Peoples R China
关键词
Gadolinium; Plastic scintillator; Neutron ambient dose equivalent meter; Energy response; Geant4; simulation;
D O I
10.1016/j.radmeas.2021.106582
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
It has been demonstrated that the gadolinium-core plastic scintillator sphere is a stable, highly sensitive, transportable, and cost-efficient neutron detector made of environmentally friendly components. This detector comprises a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. In this study, we conducted simulations to investigate the feasibility of obtaining accurate neutron ambient dose equivalent measurements using this type of detector. The Geant4 code based on the Monte Carlo method was employed to calculate the detector light output spectra for different neutron energies and the response function of the high energy part above 3 MeVee. The neutron energy responses of the detector were combined in an appropriate manner to match the energy-dependent neutron fluence to the ambient dose equivalent conversion coefficients. The Monte Carlo simulation results were used to optimize the thickness of the metal gadolinium core and plastic scintillator. The simulation results showed that a metal gadolinium core with a thickness of several hundred microns is a suitable choice considering manufacturing costs and the detector's efficiency. In addition, this type of detector with the plastic scintillator sphere size of 8" can predict the neutron ambient dose equivalent with good accuracy over a wide energy range from 0.01 eV to 20 MeV, Although it underestimated the neutron dose equivalent in the energy range from 10 keV to about 5 MeV and overestimated it in the energy interval from 5 MeV to 20 MeV.
引用
收藏
页数:7
相关论文
共 26 条
  • [1] Comparison of the neutron ambient dose equivalent and ambient absorbed dose calculations with different GEANT4 physics lists
    Ribeiro, Rosane Moreira
    Souza-Santos, Denison
    RADIATION PHYSICS AND CHEMISTRY, 2017, 139 : 179 - 183
  • [2] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [3] The Design of an Ambient Neutron Dose-Equivalent Meter
    Xia Wenming
    Jia Mingchun
    Guo Zhirong
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (08): : 84501 - 1
  • [4] Ambient Dose Equivalent Per Therapeutic Dose for 250 Mev Proton Interactions in Tissues using GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S704 - S705
  • [5] Neutron and Photon Fluence Distributions and Ambient Dose Equivalents for 250 MeV Proton Interactions in Tissue Using Geant4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Study on GEANT4 Code Applications to Dose Calculation Using Imaging Data
    Lee, Jeong Ok
    Kang, Jeong Ku
    Kim, Jhin Kee
    Kwon, Hyeong Cheol
    Kim, Jung Soo
    Kim, Bu Gil
    Jeong, Dong Hyeok
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 195 - 198
  • [7] Study on GEANT4 code applications to dose calculation using imaging data
    Jeong Ok Lee
    Jeong Ku Kang
    Jhin Kee Kim
    Hyeong Cheol Kwon
    Jung Soo Kim
    Bu Gil Kim
    Dong Hyeok Jeong
    Journal of the Korean Physical Society, 2015, 67 : 195 - 198
  • [8] On the design of experiments based on plastic scintillators using GEANT4 simulations
    Ros, G.
    Saez-Cano, G.
    Medina-Tanco, G. A.
    Supanitsky, A. D.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 153 : 140 - 151
  • [9] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [10] Assessment of optical photon collection in a large plastic scintillator using Geant4-Gate code
    Ghorbani, P.
    Sardari, D.
    Azimirad, R.
    Hosntalab, M.
    OPTIK, 2018, 158 : 305 - 311