On the design of experiments based on plastic scintillators using GEANT4 simulations

被引:7
|
作者
Ros, G. [1 ]
Saez-Cano, G. [1 ]
Medina-Tanco, G. A. [2 ]
Supanitsky, A. D. [3 ]
机构
[1] Univ Alcala, Dept Fis & Matemat, Alcala De Henares, Spain
[2] Univ Nacl Autonoma Mexico, Inst Ciencias Nucl, Mexico City, DF, Mexico
[3] CONICET UBA, Inst Astron & Fis Espacio, Buenos Aires, DF, Argentina
关键词
Plastic scintillator; Geant4; simulations; Coating; Pulses; Efficiency; PERFORMANCE; DOSIMETRY; COUNTERS; IMPACT;
D O I
10.1016/j.radphyschem.2018.09.021
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multiplier (PMT) but now silicon photo-multipliers (SiPM) are evolving as a promising robust alternative, specially in space born experiments since plastic scintillators may be a light option for low Earth orbit missions. Therefore it is timely to make a new analysis of the optimal design for experiments based on plastic scintillators in realistic conditions in such a configuration. We analyze here their response to an isotropic flux of electron and proton primaries in the energy range from 1 MeV to 1 GeV, a typical scenario for cosmic ray or space weather experiments, through detailed GEANT4 simulations. First, we focus on the effect of increasing the ratio between the plastic volume and the area of the photo-detector itself and, second, on the benefits of using a reflective coating around the plastic, the most common technique to increase light collection efficiency. In order to achieve a general approach, it is necessary to consider several detector setups. Therefore, we have performed a full set of simulations using the highly tested GEANT4 simulation tool: several parameters have been analyzed such as the energy lost in the coating, the deposited energy in the scintillator, the optical absorption, the fraction of scintillation photons that are not detected, the light collection at the photo-detector, the pulse shape and its time parameters and finally, other design parameters as the surface roughness, the coating reflectivity and the case of a scintillator with two decay components. This work could serve as a guide on the design of future experiments based on the use of plastic scintillators.
引用
收藏
页码:140 / 151
页数:12
相关论文
共 50 条
  • [1] Energy resolution experiments of conical organic scintillators and a comparison with Geant4 simulations
    Sosa, C. S.
    Thompson, S. J.
    Chichester, D. L.
    Clarke, S. D.
    Di Fulvio, A.
    Pozzi, S. A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 77 - 84
  • [2] Geant4 simulation of plastic scintillators for a prototype μSR spectrometer
    XU Wenzhen
    LIU Yanfen
    TAN Zongquan
    XIAO Ran
    KONG Wei
    YE Bangjiao
    [J]. Nuclear Science and Techniques, 2013, 24 (04) : 52 - 58
  • [3] Geant4 simulation of plastic scintillators for a prototype μSR spectrometer
    Xu Wenzhen
    Liu Yanfen
    Tan Zongquan
    Xiao Ran
    Kong Wei
    Ye Bangjiao
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2013, 24 (04)
  • [4] Computational modeling for the evaluation of suppressed scintillation yields in plastic scintillators using Geant4
    Kikuta, Shun
    Sakata, Dousatsu
    Fukuda, Shigekazu
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 89 : 258 - 264
  • [5] Ray Tracing Simulations In Scintillators: a Comparison Between SLitrani and Geant4
    Pizzichemi, Marco
    Auffray, Etiennette
    Chipaux, Remi
    Cucciati, Giacomo
    Di Vara, Nicolas
    Ghezzi, Alessio
    Iaconelli, Riccardo
    Lecoq, Paul
    Lucchini, Marco Toliman
    Knapitsch, Arno
    Paganoni, Marco
    Pauwels, Kristof
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1712 - 1716
  • [6] GEANT4 simulations of small cosmic ray detection modules based on scintillators and WLS bars
    La Rocca, P.
    Nicotra, D.
    Riggi, F.
    [J]. JOURNAL OF INSTRUMENTATION, 2018, 13
  • [7] Simulations of the HEX payload using Geant4
    Sudhakar, Manju
    Vadawale, Santosh
    Sreekurnar, P.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2351 - +
  • [8] Comparison of scattering experiments using synchrotron radiation with Monte Carlo simulations using Geant4
    Gerlach, M.
    Krumrey, M.
    Cibik, L.
    Mueller, P.
    Ulm, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (02): : 339 - 343
  • [9] BC404 scintillators as gamma locators studied via Geant4 simulations
    Cortes, M. L.
    Hoischen, R.
    Eisenhauer, K.
    Gerl, J.
    Pietralla, N.
    [J]. JOURNAL OF INSTRUMENTATION, 2014, 9
  • [10] Silicon Photomultipliers based neutron detector design: validation of Geant4 simulations
    Kumar, Shashank
    Herzkamp, Matthias
    van Waasen, Stefan
    [J]. HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114