摘要
Plastic scintillators are widely used as particle detectors in many fields, mainly, medicine, particle physics and astrophysics. Traditionally, they are coupled to a photo-multiplier (PMT) but now silicon photo-multipliers (SiPM) are evolving as a promising robust alternative, specially in space born experiments since plastic scintillators may be a light option for low Earth orbit missions. Therefore it is timely to make a new analysis of the optimal design for experiments based on plastic scintillators in realistic conditions in such a configuration. We analyze here their response to an isotropic flux of electron and proton primaries in the energy range from 1 MeV to 1 GeV, a typical scenario for cosmic ray or space weather experiments, through detailed GEANT4 simulations. First, we focus on the effect of increasing the ratio between the plastic volume and the area of the photo-detector itself and, second, on the benefits of using a reflective coating around the plastic, the most common technique to increase light collection efficiency. In order to achieve a general approach, it is necessary to consider several detector setups. Therefore, we have performed a full set of simulations using the highly tested GEANT4 simulation tool: several parameters have been analyzed such as the energy lost in the coating, the deposited energy in the scintillator, the optical absorption, the fraction of scintillation photons that are not detected, the light collection at the photo-detector, the pulse shape and its time parameters and finally, other design parameters as the surface roughness, the coating reflectivity and the case of a scintillator with two decay components. This work could serve as a guide on the design of future experiments based on the use of plastic scintillators.
引用
下载
收藏
页码:140 / 151
页数:12
相关论文
共 50 条
  • [31] Simulations of therapeutic proton beam formation with GEANT4
    Kim, A
    Kim, JW
    Hahn, I
    Schreuder, N
    Farr, J
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2005, 47 (02) : 197 - 201
  • [32] Geant4 applications and developments for medical physics experiments
    Rodrigues, P
    Moura, R
    Ortigao, C
    Peralta, L
    Pia, MG
    Trindade, A
    Varela, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (04) : 1412 - 1419
  • [33] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [34] PSF and S/P in mammography:: A validation of simulations using the GEANT4 code
    Grabski, V
    Brandan, ME
    Ruiz-Trejo, C
    Villaseñor, Y
    MEDICAL PHYSICS, 2005, 32 (06) : 1911 - 1911
  • [35] Optical physics of scintillation imagers by GEANT4 simulations
    Lo Meo, Sergio
    Baldazzi, Giuseppe
    Bennati, Paolo
    Bollini, Dante
    Cencelli, Valentino O.
    Cinti, Maria N.
    Moschini, Giuliano
    Lanconelli, Nico
    Navarria, Francesco L.
    Pani, Roberto
    Pellegrini, Rosanna
    Perrotta, Andrea
    Vittorini, Francesca
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 259 - 260
  • [36] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [37] GEANT4 applications and developments for medical physics experiments
    Rodrigues, P
    Moura, R
    Peralta, L
    Pia, MG
    Trindade, A
    Varela, J
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1751 - 1755
  • [38] Study of Thermal Neutron Albedo for Hydrogenous Materials Using Geant4 Simulations
    Hussain, Muhammad Mubashar
    Mirza, Sikander M.
    Rehman, Shakeel Ur
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [39] Geant4 based cosmic-ray background simulator for balloon experiments
    Mizuno, T
    Fukazawa, Y
    Hirano, K
    Mizushima, H
    Ogata, S
    Handa, T
    Kamae, T
    Lindner, T
    Ozaki, M
    Sjogren, M
    Valtersson, P
    Kelly, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 442 - 446
  • [40] GEANT4 SIMULATIONS OF A BEAM SHAPING ASSEMBLY DESIGN AND OPTIMIZATION FOR THERMAL/EPITHERMAL NEUTRONS
    Avagyan, R.
    Avetisyan, R.
    Ivanyan, V.
    Kerobyan, I.
    ACTA PHYSICA POLONICA B, 2017, 48 (10): : 1693 - 1699