Simulated design of neutron ambient dose equivalent meter with gadolinium core plastic scintillator using Geant4 code

被引:1
|
作者
Hong, B. [1 ]
Xu, Y. [2 ]
Chen, N. [2 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Anhui Med Univ, Teaching & Res Sect Nucl Med, Hefei 230032, Peoples R China
关键词
Gadolinium; Plastic scintillator; Neutron ambient dose equivalent meter; Energy response; Geant4; simulation;
D O I
10.1016/j.radmeas.2021.106582
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
It has been demonstrated that the gadolinium-core plastic scintillator sphere is a stable, highly sensitive, transportable, and cost-efficient neutron detector made of environmentally friendly components. This detector comprises a metal gadolinium core inserted at the center of a high-scale plastic scintillator sphere. In this study, we conducted simulations to investigate the feasibility of obtaining accurate neutron ambient dose equivalent measurements using this type of detector. The Geant4 code based on the Monte Carlo method was employed to calculate the detector light output spectra for different neutron energies and the response function of the high energy part above 3 MeVee. The neutron energy responses of the detector were combined in an appropriate manner to match the energy-dependent neutron fluence to the ambient dose equivalent conversion coefficients. The Monte Carlo simulation results were used to optimize the thickness of the metal gadolinium core and plastic scintillator. The simulation results showed that a metal gadolinium core with a thickness of several hundred microns is a suitable choice considering manufacturing costs and the detector's efficiency. In addition, this type of detector with the plastic scintillator sphere size of 8" can predict the neutron ambient dose equivalent with good accuracy over a wide energy range from 0.01 eV to 20 MeV, Although it underestimated the neutron dose equivalent in the energy range from 10 keV to about 5 MeV and overestimated it in the energy interval from 5 MeV to 20 MeV.
引用
收藏
页数:7
相关论文
共 26 条
  • [21] Simulation study using GEANT4 Monte Carlo code for a Gd-coated resistive plate chamber as a thermal neutron detector
    Jamil, M.
    Jo, Hyun Yong
    Rhee, J. T.
    Jeon, Y. J.
    RADIATION MEASUREMENTS, 2010, 45 (07) : 840 - 843
  • [22] Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the GEANT4 Monte Carlo code
    Guan, Fada
    Peeler, Christopher
    Bronk, Lawrence
    Geng, Changran
    Taleei, Reza
    Randeniya, Sharmalee
    Ge, Shuaiping
    Mirkovic, Dragan
    Grosshans, David
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2015, 42 (11) : 6234 - 6247
  • [23] Determination of Dose Distributions by Monte-Carlo Simulation of 6 MV Photon Beam of Varian VitalBeam Accelerator Using Geant4 Multithreaded Code
    Chiuyo, Julius
    Lugendo, Innocent
    Muhogora, Wilbroad
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (02) : 181 - 188
  • [24] A Comprehensive Study to Design A Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder (VC) Using GEANT4 Monte Carlo Simulation Code
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Analysis of the track- and dose-averaged LET and LET spectra in proton therapy using the geant4 Monte Carlo code (vol 42, pg 6234, 2015)
    Guan, Fada
    Peeler, Christopher
    Bronk, Lawrence
    Geng, Changran
    Taleei, Reza
    Randeniya, Sharmalee
    Ge, Shuaiping
    Mirkovic, Dragan
    Grosshans, David
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2018, 45 (03) : 1302 - 1302
  • [26] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147