摘要
Background: The "Geant4 Application for Tomography Emission" (GATE) toolkit comprises advanced open-source Monte Carlo (MC) code for use in medical imaging and radiotherapy simulations. This study aimed to verify the GATE toolkit results against a water phantom and then to show the dose calculation capabilities of the GATE for radiotherapy. The results were compared with three dose calculation algorithms using patients' Computerized Tomography (CT) data. Materials and Methods: A Linac with a 6 MV photon beam was simulated in the GATE code. The code was verified, head CT images of three patients were inserted into the GATE as realistic phantoms , and simulations were performed for different field sizes and angles. The Percent Depth Doses (PDDs) and transverse profiles were extracted from the GATE simulation and calculation algorithms. Their results were compared regarding the Dose Difference (DD) and gamma index for the PDDs and the Full Width at Half Maximum (FWHM) for the profiles. Results: Using the patient CT data for the PDDs, the gamma pass rate with 3%/3 mm criteria in the comparison between the GATE simulation and algorithms for all fields ranged from 89.4% to 98.8%, with an average of 92.8%. The extracted FWHMs from the GATE and algorithms were in good agreement, and their differences ranged from 0.1 to 1.2 mm. Conclusions: The GATE MC toolkit has good potential for implementation in radiotherapy Treatment Planning Systems (TPS) for dose calculations.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [2] GMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
    Jahnke, Lennart
    Fleckenstein, Jens
    Wenz, Frederik
    Hesser, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1217 - 1229
  • [3] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [4] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Adil Bardane
    Jaouad Tajmouaati
    Abdelmajid Maghnouj
    Moscow University Physics Bulletin, 2020, 75 : 58 - 62
  • [5] GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography
    Jan, S
    Collot, J
    Gallin-Martel, ML
    Martin, P
    Mayet, F
    Tournefier, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 102 - 106
  • [6] Implementation of a GEANT4 Monte Carlo code for the development of a proton therapy beam line and verification of proton beams dose distributions
    Cirrone, GAP
    Cuttone, G
    Pia, MG
    Guatelli, S
    Lo Nigro, S
    Sabini, MG
    Lo Nigro, S
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S106 - S106
  • [7] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [8] A CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
    Henderson, N.
    Murakami, K.
    Amako, K.
    Asai, M.
    Aso, T.
    Dotti, A.
    Kimura, A.
    Gerritsen, M.
    Kurashige, H.
    Perl, J.
    Sasaki, T.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [9] Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code Geant4
    Larsson, S
    Svensson, R
    Gudowska, I
    Ivanchenko, V
    Brahme, A
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 503 - 507
  • [10] Implementation of the reverse/adjoint Monte Carlo method into Geant4
    Desorgher, L.
    Lei, F.
    Santin, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 247 - 257