Influence of laser parameters on isotope fractionation and optimisation of lithium and boron isotope ratio measurements using laser ablation-multiple Faraday collector-inductively coupled plasma mass spectrometry

被引:31
|
作者
Kimura, Jun-ichi [1 ]
Chang, Qing [1 ]
Ishikawa, Tsuyoshi [2 ]
Tsujimori, Tatsuki [3 ]
机构
[1] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Dept Solid Earth Geochem, 2-15 Natsushima Cho, Yokosuka, Kanagawa 2370061, Japan
[2] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Kochi Inst Core Sample Res, 200 Monobe Otsu, Nankoku, Kochi 7838502, Japan
[3] Tohoku Univ, Ctr Northeast Asian Studies, Aoba Ku, 41 Kawauchi, Sendai, Miyagi 9808576, Japan
关键词
UV-FEMTOSECOND LASER; ICP-MS; IN-SITU; ULTRAVIOLET FEMTOSECOND; GLASS; MINERALS; ROCKS; SYSTEMATICS; DELTA-B-11; SAMPLES;
D O I
10.1039/c6ja00283h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the origin of isotope fractionation induced by the choice of laser parameters and a method for accurate in situ determination of lithium (delta Li-7) and boron (delta B-11) isotope ratios in glasses and minerals using laser ablation multiple Faraday collector inductively coupled plasma mass spectrometry (LA-MFC-ICPMS). Laser ablation parameters were examined using 266 nm femtosecond (266FsLA) and 193 nm nanosecond excimer (193ExLA) laser ablation systems for crater diameters of 30-200 mu m. We found that higher laser repetition rates and larger crater diameters have led to enhanced fractionation of lighter isotopes, as much as -8 parts per thousand for both delta Li-7 and delta B-11. Fractionation was primarily affected by the ICP aerosol loading and secondly by the thermal fractionation at the LA site. The former was accounted for by mass loading effects, which lowered the plasma temperature and led to insufficient aerosol vaporisation. The latter was related to the molten layer on the crater walls, which resulted in coarser and heavier delta Li-7 and delta B-11 aerosols that did not reach the ICP. Both processes can result in Rayleigh fractionation during aerosol formation and vaporisation. Controlled ablation using a constant crater size, repetition rate, and high laser fluence of 193ExLA enabled reproducible ablation for the standard NIST SRM 61X glasses and unknown basalt glasses. Based on the principles of isotopic fractionation deduced from our experiments, we propose a novel ablation volume correction (AVC) protocol for accurate isotopic analyses of various samples with different matrices. Both the repeatability and the laboratory bias of the delta Li-7 and delta B-11 measurements using the new AVC protocol were better than 1 parts per thousand for samples containing a few tens to a few tens of thousands ppm Li and B. We also report significant local heterogeneity of up to several parts per thousand found in some basalt glasses, but not in NIST SRM 612 and 610.
引用
收藏
页码:2305 / 2320
页数:16
相关论文
共 50 条
  • [31] Sources of uncertainty in isotope ratio measurements by inductively coupled plasma mass spectrometry
    Appelblad, PK
    Rodushkin, I
    Baxter, DC
    ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2911 - 2919
  • [32] Measurements of lead isotope ratio in cement by inductively coupled plasma mass spectrometry
    Chen, JM
    Tan, MG
    Lu, WW
    Li, YL
    Zhang, GL
    Li, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 943 - 946
  • [33] Development of in situ Li isotope analysis using laser ablation quadrupole inductively coupled plasma mass spectrometry
    Fan, Xuefei
    Sio, Corliss Kin, I
    Chu, Xu
    Jiang, Hehe
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (02)
  • [34] Comparison of 265 nm Femtosecond and 213 nm Nanosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Pb Isotope Ratio Measurements
    Masaki Ohata
    Naoko Nonose
    Ladina Dorta
    Detlef Günther
    Analytical Sciences, 2015, 31 : 1309 - 1315
  • [35] Comparison of 265 nm Femtosecond and 213 nm Nanosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Pb Isotope Ratio Measurements
    Ohata, Masaki
    Nonose, Naoko
    Dorta, Ladina
    Guenther, Detlef
    ANALYTICAL SCIENCES, 2015, 31 (12) : 1309 - 1315
  • [36] Uranium and thorium isotope ratio measurements using multiple collector inductively coupled plasma mass spectrometry with multi-ion-counting detectors
    Ellam, RM
    Tudhope, AW
    PLASMA SOURCE MASS SPECTROMETRY: APPLICATIONS AND EMERGING TECHNOLOGIES, 2003, : 391 - 403
  • [37] Influence factors and evaluation of elemental fractionation in laser ablation inductively coupled plasma mass spectrometry
    Chen, Yu-Hong
    Wang, Hai-Zhou
    Yejin Fenxi/Metallurgical Analysis, 2008, 28 (08): : 1 - 6
  • [38] On-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry using a microflow nebulizer inserted in the laser ablation chamber
    Pickhardt, C
    Izmer, AV
    Zoriy, MV
    Schaumlöffel, D
    Becker, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2006, 248 (03) : 136 - 141
  • [39] RECENT ADVANCES IN ISOTOPE RATIO MEASUREMENT BY INDUCTIVELY-COUPLED PLASMA - MULTIPLE COLLECTOR - MASS-SPECTROMETRY
    WALDER, AJ
    ENTWISTLE, A
    TAYLOR, PDP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 104 - NUCL
  • [40] Isotope abundance ratio measurements using femtosecond laser ablation ionization mass spectrometry
    Tulej, Marek
    Neubeck, Anna
    Riedo, Andreas
    Lukmanov, Rustam
    Grimaudo, Valentine
    Ligterink, Niels F. W.
    Ivarsson, Magnus
    Bach, Wolfgang
    de Koning, Coenraad
    Wurz, Peter
    JOURNAL OF MASS SPECTROMETRY, 2020, 55 (12):