Isotope abundance ratio measurements using femtosecond laser ablation ionization mass spectrometry

被引:9
|
作者
Tulej, Marek [1 ]
Neubeck, Anna [2 ]
Riedo, Andreas [1 ]
Lukmanov, Rustam [1 ]
Grimaudo, Valentine [1 ]
Ligterink, Niels F. W. [3 ]
Ivarsson, Magnus [4 ,5 ]
Bach, Wolfgang [6 ]
de Koning, Coenraad [1 ]
Wurz, Peter [1 ]
机构
[1] Univ Bern, Phys Inst, Space Res & Planetary Sci, Bern, Switzerland
[2] Uppsala Univ, Dept Geol Sci, Uppsala, Sweden
[3] Univ Bern, Ctr Space & Habitabil, Bern, Switzerland
[4] Univ Southern Denmark, Dept Biol, Odense, Denmark
[5] Swedish Museum Nat Hist, Dept Paleobiol, Stockholm, Sweden
[6] Univ Bremen, Dept Geosci, Bremen, Germany
来源
JOURNAL OF MASS SPECTROMETRY | 2020年 / 55卷 / 12期
基金
瑞典研究理事会; 瑞士国家科学基金会;
关键词
depth profiling; isotope ratio measurements; in situ chemical analysis; laser ablation ionization mass spectrometry; microfossils; miniature laser mass analyzer; time‐ of‐ flight mass spectrometry; LA-ICP-MS; IN-SITU; ELEMENTAL ANALYSIS; TIME; GEOCHEMISTRY; INSTRUMENT; REGOLITH; PROGRESS; PRECISE; SYSTEM;
D O I
10.1002/jms.4660
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate isotope ratio measurements are of high importance in various scientific fields, ranging from radio isotope geochronology of solids to studies of element isotopes fractionated by living organisms. Instrument limitations, such as unresolved isobaric inferences in the mass spectra, or cosampling of the material of interest together with the matrix material may reduce the quality of isotope measurements. Here, we describe a method for accurate isotope ratio measurements using our laser ablation ionization time-of-flight mass spectrometer (LIMS) that is designed for in situ planetary research. The method is based on chemical depth profiling that allows for identifying micrometer scale inclusions embedded in surrounding rocks with different composition inside the bulk of the sample. The data used for precise isotope measurements are improved using a spectrum cleaning procedure that ensures removal of low quality spectra. Furthermore, correlation of isotopes of an element is used to identify and reject the data points that, for example, do not belong to the species of interest. The measurements were conducted using IR femtosecond laser irradiation focused on the sample surface to a spot size of ~12 mu m. Material removal was conducted for a predefined number of laser shots, and time-of-flight mass spectra were recorded for each of the ablated layers. Measurements were conducted on NIST SRM 986 Ni isotope standard, trevorite mineral, and micrometer-sized inclusions embedded in aragonite. Our measurements demonstrate that element isotope ratios can be measured with accuracies and precision at the permille level, exemplified by the analysis of B, Mg, and Ni element isotopes. The method applied will be used for in situ investigation of samples on planetary surfaces, for accurate quantification of element fractionation induced by, for example, past or present life or by geochemical processes.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Precision in Strontium Isotope Measurements by Laser Ablation Assisted Resonance Ionization Mass Spectrometry
    Sasada, S.
    Tomita, H.
    Watanabe, K.
    Higuchi, Y.
    Kawarabayashi, J.
    Iguchi, T.
    [J]. 4TH INTERNATIONAL CONFERENCE ON LASER PROBING - LAP 2008, 2009, 1104 : 173 - 178
  • [2] Determination of the isotope ratio for metal samples using a laser ablation/ionization time-of-flight mass spectrometry
    Song, K
    Cha, HK
    Kim, DY
    Min, KY
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (01) : 101 - 105
  • [3] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Mathew, Kattathu Joseph
    Ottenfeld, Chelsea
    Levesque, Steven
    Keller, Russ
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (02) : 1005 - 1017
  • [4] Matrix effects in plutonium isotope ratio measurements using thermal ionization mass spectrometry
    Kattathu Joseph Mathew
    Chelsea Ottenfeld
    Steven Levesque
    Russ Keller
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 1005 - 1017
  • [5] Recent developments in isotope ratio measurements by resonance ionization mass spectrometry
    Wendt, K
    Trautmann, N
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 161 - 168
  • [6] Characterization of femtosecond laser ablation processes on as-deposited SnAg solder alloy using laser ablation ionization mass spectrometry
    Lopez, A. Cedeno
    Grimaudo, V
    Riedo, A.
    Tulej, M.
    Wiesendanger, R.
    Lukmanov, R.
    Moreno-Garcia, P.
    Lortscher, E.
    Wurz, P.
    Broekmann, P.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 180
  • [7] Improving Precision in Resonance Ionization Mass Spectrometry: Influence of Laser Bandwidth in Uranium Isotope Ratio Measurements
    Isselhardt, B. H.
    Savina, M. R.
    Knight, K. B.
    Pellin, M. J.
    Hutcheon, I. D.
    Prussin, S. G.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (07) : 2469 - 2475
  • [8] Comparison of 265 nm Femtosecond and 213 nm Nanosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Pb Isotope Ratio Measurements
    Ohata, Masaki
    Nonose, Naoko
    Dorta, Ladina
    Guenther, Detlef
    [J]. ANALYTICAL SCIENCES, 2015, 31 (12) : 1309 - 1315
  • [9] Comparison of 265 nm Femtosecond and 213 nm Nanosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry for Pb Isotope Ratio Measurements
    Masaki Ohata
    Naoko Nonose
    Ladina Dorta
    Detlef Günther
    [J]. Analytical Sciences, 2015, 31 : 1309 - 1315
  • [10] Non-selective photoionization for isotope ratio measurements by time of flight mass spectrometry with laser ablation
    Vors, E
    Semerok, A
    Wagner, JF
    Fomichev, SV
    [J]. APPLIED SURFACE SCIENCE, 2000, 168 (1-4) : 166 - 169