Development of in situ Li isotope analysis using laser ablation quadrupole inductively coupled plasma mass spectrometry

被引:1
|
作者
Fan, Xuefei [1 ,2 ,4 ]
Sio, Corliss Kin, I [1 ,4 ]
Chu, Xu [1 ]
Jiang, Hehe [1 ,3 ]
机构
[1] Univ Toronto, Dept Earth Sci, Toronto, ON, Canada
[2] Univ Washington, Dept Earth & Space Sci, Seattle, WA USA
[3] Chinese Acad Sci, Inst Geol & Geophys, State Key Lab Lithospher Evolut, Beijing, Peoples R China
[4] Univ Toronto, Dept Earth Sci, Toronto, ON M5S 3B1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
FRACTIONATION; DIFFUSION; RATIOS; ROCKS;
D O I
10.1002/rcm.9668
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale: Lithium isotope geochemistry is an important tool in the studies of Earth and planetary materials. In situ Li isotope analyses are typically performed using secondary ion mass spectrometry (SIMS) or laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICPMS), but these instruments are not widely accessible. Here, the capability of laser ablation quadrupole ICPMS for conducting Li isotopic analyses is evaluated.Methods: An array of MPI-DING and USGS silicate glass reference materials was analyzed repeatedly over the course of 6 months. These materials range from komatiite to rhyolite in terms of silica content (45.5-75.6 wt%) with 9-45 ppm Li. Their Li isotope compositions have been previously characterized so that matrix effects could be tested with these reference materials. Analyses were conducted using an NWR193 laser ablation system coupled to an Agilent 7900 ICPMS system.Results: Analytical precision is primarily limited by Li concentration in the samples. For samples with-9 ppm Li, the internal precision is 6%o (2 SD, 150 p.m spot diameter), whereas that for a sample with similar to 45 ppm Li is 4%o (2 SD, 120 p.m spot diameter). The technique is somewhat sensitive to sample matrix: samples with SiO2 content that deviates from the bracketing standard display fractionated delta Li-7, necessitating correction using a session-specific matrix correction curve.Conclusion: Lithium isotope analysis by ns-LA-QICPMS is worthwhile for samples with high Li concentrations and when a matrix-matched standard can be obtained. Although the precision of this method is not as high as those achievable with SIMS and LA-MC-ICPMS, it remains adequate for resolving large isotope fractionations found in natural and laboratory settings.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Laser Ablation Inductively Coupled Mass Spectrometry for in situ Trace Element and Isotope Analysis
    Ash, R. D.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 538 - 539
  • [2] Analysis of In situ Pb Isotope in Sulfides by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang Wen
    Hu Zhao-Chu
    Jin Zhen-Min
    Liu Yong-Sheng
    Ling Wen-Li
    Hu Qing-Hai
    Fu Jia-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 14 - 22
  • [3] In situ analysis of trace elements in quartz by using laser ablation inductively coupled plasma mass spectrometry
    Flem, B
    Larsen, RB
    Grimstvedt, A
    Mansfeld, J
    CHEMICAL GEOLOGY, 2002, 182 (2-4) : 237 - 247
  • [4] Laser ablation inductively coupled plasma mass spectrometry
    Durrant, SF
    SURFACES, VACUUM, AND THEIR APPLICATIONS, 1996, (378): : 94 - 97
  • [5] Laser ablation inductively coupled plasma mass spectrometry
    Alexander, ML
    Smith, MR
    Hartman, JS
    Mendoza, A
    Koppenaal, DW
    APPLIED SURFACE SCIENCE, 1998, 127 : 255 - 261
  • [6] Solid sample analysis using laser ablation inductively coupled plasma mass spectrometry
    Günther, D
    Hattendorf, B
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) : 255 - 265
  • [7] In situ analysis of trace elements and isotope ratios in fish otoliths using laser ablation sector field inductively coupled plasma mass spectrometry
    Thorrold, SR
    Shuttleworth, S
    CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 2000, 57 (06) : 1232 - 1242
  • [8] Development of routines for simultaneous in situ chemical composition and stable Si isotope ratio analysis by femtosecond laser ablation inductively coupled plasma mass spectrometry
    Frick, Daniel A.
    Schuessler, Jan A.
    von Blanckenburg, Friedhelm
    ANALYTICA CHIMICA ACTA, 2016, 938 : 33 - 43
  • [9] Applications of inductively coupled plasma mass spectrometry and laser ablation inductively coupled plasma mass spectrometry in materials science
    Becker, JS
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) : 1805 - 1820
  • [10] The effect of matrix interferences on in situ boron isotope analysis by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Standish, Christopher D.
    Chalk, Thomas B.
    Babila, Tali L.
    Milton, J. Andy
    Palmer, Martin R.
    Foster, Gavin L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (10) : 959 - 968