Influence of laser parameters on isotope fractionation and optimisation of lithium and boron isotope ratio measurements using laser ablation-multiple Faraday collector-inductively coupled plasma mass spectrometry

被引:31
|
作者
Kimura, Jun-ichi [1 ]
Chang, Qing [1 ]
Ishikawa, Tsuyoshi [2 ]
Tsujimori, Tatsuki [3 ]
机构
[1] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Dept Solid Earth Geochem, 2-15 Natsushima Cho, Yokosuka, Kanagawa 2370061, Japan
[2] Japan Agcy Marine Earth Sci & Technol JAMSTEC, Kochi Inst Core Sample Res, 200 Monobe Otsu, Nankoku, Kochi 7838502, Japan
[3] Tohoku Univ, Ctr Northeast Asian Studies, Aoba Ku, 41 Kawauchi, Sendai, Miyagi 9808576, Japan
关键词
UV-FEMTOSECOND LASER; ICP-MS; IN-SITU; ULTRAVIOLET FEMTOSECOND; GLASS; MINERALS; ROCKS; SYSTEMATICS; DELTA-B-11; SAMPLES;
D O I
10.1039/c6ja00283h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the origin of isotope fractionation induced by the choice of laser parameters and a method for accurate in situ determination of lithium (delta Li-7) and boron (delta B-11) isotope ratios in glasses and minerals using laser ablation multiple Faraday collector inductively coupled plasma mass spectrometry (LA-MFC-ICPMS). Laser ablation parameters were examined using 266 nm femtosecond (266FsLA) and 193 nm nanosecond excimer (193ExLA) laser ablation systems for crater diameters of 30-200 mu m. We found that higher laser repetition rates and larger crater diameters have led to enhanced fractionation of lighter isotopes, as much as -8 parts per thousand for both delta Li-7 and delta B-11. Fractionation was primarily affected by the ICP aerosol loading and secondly by the thermal fractionation at the LA site. The former was accounted for by mass loading effects, which lowered the plasma temperature and led to insufficient aerosol vaporisation. The latter was related to the molten layer on the crater walls, which resulted in coarser and heavier delta Li-7 and delta B-11 aerosols that did not reach the ICP. Both processes can result in Rayleigh fractionation during aerosol formation and vaporisation. Controlled ablation using a constant crater size, repetition rate, and high laser fluence of 193ExLA enabled reproducible ablation for the standard NIST SRM 61X glasses and unknown basalt glasses. Based on the principles of isotopic fractionation deduced from our experiments, we propose a novel ablation volume correction (AVC) protocol for accurate isotopic analyses of various samples with different matrices. Both the repeatability and the laboratory bias of the delta Li-7 and delta B-11 measurements using the new AVC protocol were better than 1 parts per thousand for samples containing a few tens to a few tens of thousands ppm Li and B. We also report significant local heterogeneity of up to several parts per thousand found in some basalt glasses, but not in NIST SRM 612 and 610.
引用
收藏
页码:2305 / 2320
页数:16
相关论文
共 50 条
  • [41] In situ Mg isotope measurements of biogenic carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry: A new tool to understand biomineralisation
    Sadekov, Aleksey
    Lloyd, Nicholas S.
    Misra, Sambuddha
    D'Olivo, Juan Pablo
    McCulloch, Malcolm
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [42] Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry
    Varga, Z.
    Krachler, M.
    Nicholl, A.
    Ernstberger, M.
    Wiss, T.
    Wallenius, M.
    Mayer, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (06) : 1076 - 1080
  • [43] Isotope-ratio measurements of lead in NIST standard reference materials by multiple-collector inductively coupled plasma mass spectrometry
    Platzner, I
    Ehrlich, S
    Halicz, L
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) : 624 - 628
  • [44] Isotope-ratio measurements of lead in NIST standard reference materials by multiple-collector inductively coupled plasma mass spectrometry
    I. Platzner
    S. Ehrlich
    L. Halicz
    Analytical and Bioanalytical Chemistry, 2001, 370 : 624 - 628
  • [45] Influence of room temperature on magnesium isotope measurements by multi-collector inductively coupled plasma mass spectrometry
    Zhang, Xing-Chao
    Zhang, An-Yu
    Zhang, Zhao-Feng
    Huang, Fang
    Yu, Hui-Min
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (13) : 1026 - 1030
  • [46] Study of plasma parameters influencing fractionation in laser ablation-inductively coupled plasma-mass spectrometry
    Gaeckle, M.
    Merten, D.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (12) : 991 - 1001
  • [47] Laser Ablation Inductively Coupled Mass Spectrometry for in situ Trace Element and Isotope Analysis
    Ash, R. D.
    MICROSCOPY AND MICROANALYSIS, 2009, 15 : 538 - 539
  • [48] High precision calcium isotope ratio measurements using a magnetic sector multiple collector inductively coupled plasma mass spectrometer
    Wieser, ME
    Buhl, D
    Bouman, C
    Schwieters, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) : 844 - 851
  • [49] Laser Ablation Molecular Isotopic Spectrometry: Parameter influence on boron isotope measurements
    Mao, Xianglei
    Bol'shakov, Alexander A.
    Perry, Dale L.
    Sorkhabi, Osman
    Russo, Richard E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (08) : 604 - 609
  • [50] Investigation on elemental and isotopic fractionation during 196 nm femtosecond laser ablation multiple collector inductively coupled plasma mass spectrometry
    Horn, Ingo
    von Blanckenburg, Friedhelm
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (04) : 410 - 422