On-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry using a microflow nebulizer inserted in the laser ablation chamber

被引:61
|
作者
Pickhardt, C
Izmer, AV
Zoriy, MV
Schaumlöffel, D
Becker, JS [1 ]
机构
[1] Res Ctr Juelich, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] CNRS, Grp Bioinorgan Analyt Chem, UMR 5034, F-64053 Pau, France
关键词
microflow nebulizer; laser ablation; ICP-MS; on-line isotope dilution analysis;
D O I
10.1016/j.ijms.2005.11.001
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Laser ablation ICP-MS (inductively coupled plasma mass spectrometry) is becoming one of the most important analytical techniques for fast determination of trace impurities in solid samples. Quantification of analytical results requires matrix-matched standards, which are in some cases (e.g., high-purity metals, proteins separated by 2D gel electrophoresis) difficult to obtain or prepare. In order to overcome the quantification problem a special arrangement for on-line solution-based calibration has been proposed in laser ablation ICP-MS by the insertion of a microflow nebulizer in the laser ablation chamber. This arrangement allows an easy, accurate and precise quantification by on-line isotope dilution using a defined standard solution with an isotope enriched tracer nebulized to the laser-ablated sample material. An ideal matrix matching in LA-ICP-MS is therefore obtained during the measurement. The figures of merit of this arrangement with a microflow nebulizer inserted in the laser ablation chamber and applications of on-line isotope dilution in LA-ICP-MS on two different types of sample material (NIST glass SRM 612 and NIST apple leaves SRM 1515) will be described. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [1] On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials
    Fernandez, Beatriz
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, J. Ignacio
    Malherbe, Julien
    Garcia-Fonseca, Sergio
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2014, 851 : 64 - 71
  • [2] Laser ablation inductively coupled plasma mass spectrometry
    Durrant, SF
    SURFACES, VACUUM, AND THEIR APPLICATIONS, 1996, (378): : 94 - 97
  • [3] Laser ablation inductively coupled plasma mass spectrometry
    Alexander, ML
    Smith, MR
    Hartman, JS
    Mendoza, A
    Koppenaal, DW
    APPLIED SURFACE SCIENCE, 1998, 127 : 255 - 261
  • [4] Determination of Ag, Tl, and Pb in few milligrams of platinum nanoclusters by on-line isotope dilution in laser ablation inductively coupled plasma mass spectrometry
    Becker, JS
    Pickhardt, C
    Pompe, W
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 237 (01) : 13 - 17
  • [5] A viscous film sample chamber for Laser Ablation Inductively Coupled Plasma - Mass Spectrometry
    Monticelli, Damiano
    Civati, Davide
    Giussani, Barbara
    Dossi, Carlo
    Spanu, Davide
    Recchia, Sandro
    TALANTA, 2018, 179 : 100 - 106
  • [7] Flow Peak Detection Using Penalized Asymmetric Least Squares in On-line Isotope Dilution-Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Anagisawa, Kayo
    Okota, Hiromi
    Ujimoto, Katsushige
    Akagai, Yoshitaka
    BUNSEKI KAGAKU, 2024, 73 (09) : 515 - 522
  • [8] Quantitative Bioimaging of Platinum via Online Isotope Dilution Laser Ablation-Inductively Coupled Plasma Mass Spectrometry
    Bauer, Oliver Bolle
    Koeppen, Christina
    Sperling, Michael
    Schurek, Hans-Joachim
    Ciarimboli, Giuliano
    Karst, Uwe
    ANALYTICAL CHEMISTRY, 2018, 90 (11) : 7033 - 7039
  • [9] Laser ablation inductively coupled plasma mass spectrometry with a compact laser source
    Baker, SA
    Smith, BW
    Winefordner, JA
    APPLIED SPECTROSCOPY, 1997, 51 (12) : 1918 - 1921
  • [10] Development of an on-line isotope dilution laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) method for determination of boron in silicon wafers
    Yang, Chao-Kai
    Chi, Po-Hsiang
    Lin, Yong-Chine
    Sun, Yuh-Chang
    Yang, Mo-Hsiung
    TALANTA, 2010, 80 (03) : 1222 - 1227