Automated analysis for the respiratory kinetics with the screening dynamic chest radiography using a flat-panel detector system

被引:2
|
作者
Tanaka, R [1 ]
Sanada, S [1 ]
Kobayashi, T [1 ]
Suzuki, M [1 ]
Matsui, T [1 ]
Inoue, H [1 ]
机构
[1] Kanazawa Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Kanazawa, Ishikawa 9200942, Japan
关键词
respiratory kinetics; automated analysis; dynamic chest radiography;
D O I
10.1016/S0531-5131(03)00359-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a new method for analyzing respiratory kinetics, such as the movement of the diaphragm, the movement of the chest wall, and the respiratory change in X-ray translucency in local lung fields on dynamic chest radiographs. Our approach could provide some respiratory kinetic information as well as severity of disease on image findings. In addition, the results of the movement analysis of the diaphragm well correlated with respiratory functional tests. It was concluded that dynamic chest radiography and our analysis method may be an effective aid for the evaluation of chronic obstructive pulmonary disease, pulmonary fibrosis, pneumonia, and other pulmonary diseases. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [41] A testing system of DR based on the Flat-panel detector
    Liang, LH
    Guo, WM
    [J]. ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1915 - 1918
  • [42] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    [J]. Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [43] GE a-Si flat-panel detector performance in industrial digital radiography
    Mohr, GA
    Bueno, C
    [J]. INSIGHT, 2002, 44 (10) : 631 - 633
  • [44] Comparing image quality of flat-panel chest radiography with storage phosphor radiography and film-screen radiography
    Ganten, M
    Radeleff, B
    Kampschulte, A
    Daniels, MD
    Kauffmann, GW
    Hansmann, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) : 171 - 176
  • [45] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2003, 226 (01) : 221 - 230
  • [46] Development of patient collation system by kinetic analysis for chest dynamic radiogram with flat panel detector
    Tsuchiya, Yuichiro
    Kodera, Yoshie
    [J]. MEDICAL IMAGING 2006: PACS AND IMAGING INFORMATICS, 2006, 6145
  • [47] Evaluation of pulmonary function using breathing chest radiography with a dynamic flat panel detector - Primary results in pulmonary diseases
    Tanaka, Rie
    Sanada, Shigeru
    Okazaki, Nobuo
    Kobayashi, Takeshi
    Fujimura, Masaki
    Yasui, Masahide
    Matsui, Takeshi
    Nakayama, Kazuya
    Nanbu, Yuko
    Matsui, Osamu
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (10) : 735 - 745
  • [48] Digital chest radiography with a selenium-based flat-panel detector versus a storage phosphor system: Comparison of soft-copy images
    Goo, JM
    Im, JG
    Kim, JH
    Seo, JB
    Kim, TS
    Shine, SJ
    Lee, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) : 1013 - 1018
  • [49] Functional shoulder radiography with use of a dynamic flat panel detector
    Sakuda K.
    Sanada S.
    Tanaka R.
    Kitaoka K.
    Hayashi N.
    Matsuura Y.
    [J]. Radiological Physics and Technology, 2014, 7 (2) : 254 - 261
  • [50] Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: Comparison with a computed radiographic system
    Tanaka N.
    Yano Y.
    Yabuuchi H.
    Akasaka T.
    Sasaki M.
    Ohki M.
    Morishita J.
    [J]. Radiological Physics and Technology, 2013, 6 (1) : 162 - 169