Digital chest radiography with a selenium-based flat-panel detector versus a storage phosphor system: Comparison of soft-copy images

被引:31
|
作者
Goo, JM
Im, JG
Kim, JH
Seo, JB
Kim, TS
Shine, SJ
Lee, W
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Chongro Gu, Seoul 110744, South Korea
[2] SNUMRC, Inst Radiat Med, Chongro Gu, Seoul 110744, South Korea
[3] Gachon Med Sch, Gil Medf Ctr, Dept Radiol, Namdong Gu, Inchon 405220, South Korea
[4] Sungkyunkwan Univ, Coll Med, Samsung Med Ctr, Dept Radiol,Kangnam Ku, Seoul 135710, South Korea
关键词
D O I
10.2214/ajr.175.4.1751013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, We compared the soft-copy images produced by a digital chest radiograph system that uses a flat-panel X-ray detector based on amorphous selenium with images produced by a storage phosphor radiography system for the visualization of anatomic regions of the chest. MATERIALS AND METHODS. Two chest radiologists and two residents analyzed 46 pairs of posteroanterior chest radiographs on high-resolution video monitors (2560 x 2048 x 8 bits). In each pair, one radiograph was obtained with a storage phosphor radiography system, and the other radiograph was obtained with a selenium-based flat-panel detector radiography system. Each pair of radiographs was obtained at the same exposure settings. The interpreter rated the visibility and radiographic quality of 11 different anatomic regions. Each pair of images was ranked on a five-point scale (1 = prefer image A, 3 = no preference, 5 = prefer image B) for preference of technique. Statistical significance of preference was determined using the Wilcoxon's signed rank test. RESULTS. The interpreters had a statistically significant preference for the selenium-based radiography system in six (unobscured lung, hilum, rib, minor fissure, heart border and overall appearance) of 11 anatomic regions (p < 0.001) and for the storage phosphor system in two regions (proximal airway and thoracic spine) (p < 0.05), Chest radiologists strongly preferred selmium-based images in eight regions, and they did not prefer storage phosphor images in any region. CONCLUSION. The soft-copy images produced by the selenium-based radiography system were perceived as equal or superior to those produced by the storage phosphor system in most but not all anatomic regions.
引用
收藏
页码:1013 / 1018
页数:6
相关论文
共 50 条
  • [1] Development of a selenium-based flat-panel detector for radiography and fluoroscopy
    Yamada, S
    Tsukamoto, A
    Tanaka, M
    Asahina, H
    Nishiki, M
    Suzuki, K
    Uematsu, Y
    [J]. CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 542 - 547
  • [2] Digital thorax radiography: flat-panel detector or storage phosphor plates
    Schaefer-Prokop, C
    Uffmann, M
    Sailer, J
    Kabalan, N
    Herold, C
    Prokop, M
    [J]. RADIOLOGE, 2003, 43 (05): : 351 - 361
  • [3] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [4] Detection of pulmonary edema in pigs: Storage phosphor versus amorphous selenium-based flat-panel-detector radiography
    Kim, TS
    Im, JG
    Goo, JM
    Lee, KH
    Lee, YJ
    Kim, SH
    Kim, S
    [J]. RADIOLOGY, 2002, 223 (03) : 695 - 701
  • [5] Development of a selenium-based flat-panel detector for real-time radiography and fluoroscopy
    Tsukamoto, A
    Yamada, S
    Tomisaki, T
    Tanaka, M
    Sakaguchi, T
    Asahina, H
    Nishiki, M
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 388 - 395
  • [6] Detection of simulated chest lesions by using soft-copy reading: Comparison of an amorphous silicon flat-panel-detector system and a storage-phosphor system
    Goo, JM
    Im, JG
    Lee, HJ
    Chung, MJ
    Seo, JB
    Kim, HY
    Lee, YJ
    Kang, JW
    Kim, JH
    [J]. RADIOLOGY, 2002, 224 (01) : 242 - 246
  • [7] Development and Evaluation of a selenium-based flat-panel digital x-ray detector system based on quality factor
    Park, JK
    Choi, JY
    Kang, SS
    Mun, CW
    Lee, HW
    Nam, SH
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 799 - 809
  • [8] Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: Comparison with storage phosphor radiography at different exposures by using a chest phantom
    Rapp-Bernhardt, U
    Bernhardt, TM
    Lenzen, H
    Esseling, R
    Roehl, FW
    Schiborr, M
    Theobold-Hormann, I
    Heindel, W
    [J]. RADIOLOGY, 2005, 237 (02) : 485 - 491
  • [9] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    [J]. RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [10] Optimum radiographic technique for chest radiography using a flat-panel digital detector
    Samei, E
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2002, 225 : 642 - 643