A testing system of DR based on the Flat-panel detector

被引:0
|
作者
Liang, LH [1 ]
Guo, WM [1 ]
机构
[1] BeiHang Univ, Sch Mech Engn & Automat, Beijing 100083, Peoples R China
关键词
Flat-panel detector; DR; intensifier; film-screen image; image quality;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The developing direction of X-ray testing system is to use the Flat-panel detector instead of film-screen images. Although the Flat-panel detector has many advantages, its image quality can't be better than that of film-screen (B level). By lots of experiments, the paper determines the best experiment conditions of imaging, analyzes the reasons for affecting the image quality and the performance of Flat-Panel detector, reduces noise at most. By applying the methods of imaging processing such as filtering and sharpening, the paper improves the image quality of Flat-panel, which is validated by a number of experiments of blade and IQI.
引用
收藏
页码:1915 / 1918
页数:4
相关论文
共 50 条
  • [1] Development and characterization of a flat-panel detector-based microtomography system
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Cho, MH
    Lee, SY
    [J]. ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 245 - 251
  • [2] Geometric Calibration Based on Matrix Calculation for CBCT System with a Flat-panel Detector
    Xu, Xiaofei
    Zhang, Li
    Wu, Dufan
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Experimental in vitro study to evaluate a flat-panel detector system
    Meier, S
    Mildenberger, P
    Oberholzer, K
    Krummenauer, F
    Thelen, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 875 - 879
  • [4] Se-based flat-panel detector for screening mammography
    Polischuk, B
    Savard, S
    Loustauneau, V
    Hansroul, M
    Cadieux, S
    Vaqué, A
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 582 - 589
  • [5] A gain correction method based on threshold for flat-panel detector
    Xiao, Da-Yu
    Cai, Peng-Fei
    Li, Hong
    Kang, Yan
    [J]. Dongbei Daxue Xuebao/Journal of Northeastern University, 2014, 35 (02): : 208 - 211
  • [6] Flat-panel DR detectors for radiography and fluoroscopy
    Yorkston, John
    [J]. SPECIFICATIONS PERFORMANCE EVALUATION AND QUALITY ASSURANCE OF RADIOGRAPHIC AND FLUOROSCOPIC SYSTEMS IN THE DIGITAL ERA, 2006, (30): : 177 - 228
  • [7] Indirect flat-panel detector with avalanche gain
    Zhao, W
    Hunt, DC
    Tanioka, K
    Rowlands, JA
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 150 - 161
  • [8] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [9] Development of a selenium-based flat-panel detector for radiography and fluoroscopy
    Yamada, S
    Tsukamoto, A
    Tanaka, M
    Asahina, H
    Nishiki, M
    Suzuki, K
    Uematsu, Y
    [J]. CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 542 - 547
  • [10] Imaging and Dosimetric Study on Direct Flat-Panel Detector-Based Digital Mammography System
    Sharma, Reena
    Sharma, S. D.
    Sarkar, P. S.
    Datta, D.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 255 - 263