Experimental in vitro study to evaluate a flat-panel detector system

被引:3
|
作者
Meier, S
Mildenberger, P
Oberholzer, K
Krummenauer, F
Thelen, M
机构
[1] Univ Mainz Klinikum, Klin & Poliklin Radiol, D-55101 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Med Biometrie Epidemiol & Informat, Mainz, Germany
关键词
flat panel detector; digital radiography; phantom study; models; skeletal; conventional radiology;
D O I
10.1055/s-2004-813141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the contrast-detail performance of a flat-panel detector system, we performed a comparative study of this flat-panel system versus storage phosphor and conventional screen-film systems. Materials and Methods: Bone models made of human humeri were prepared with foreign bodies, fracture lines and drilled holes to create artificial fractures, osteolyses or metastases. Immersed in a water bath, hard copy images of these models were acquired with the same exposure dose (55 W; 3.2 mAs) on the flat-panel detector, two state-of-the-art storage phosphor systems (PCR(R), ADC(R)) and two conventional screen-film systems (Insight(R), T-Mat(R)). Using a standardized protocol with a 4-point scale for a lesion, 220 different images were analyzed as to their appearance by 5 independent radiologists. The statistical significance of the differences between the used modalities and the observers was determined with a sign test. Results: Especially the drilled holes showed differences between the modalities. The flat-panel detector showed significantly slightly better results locally than the two storage phosphor systems. The same applied to the Insight(R) screen-film systems, but the intraindividual differences between the modalities were not clinically relevant. Conclusion: Under the conditions of the chosen experimental design, the flat-panel detector showed results comparable to the conventional screen-film and the state of the art storage phosphor radiographs. The use in skeletal radiography is possible.
引用
收藏
页码:875 / 879
页数:5
相关论文
共 50 条
  • [1] A testing system of DR based on the Flat-panel detector
    Liang, LH
    Guo, WM
    [J]. ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1915 - 1918
  • [2] Experimental verification of ion range calculation in a treatment planning system using a flat-panel detector
    Telsemeyer, Julia
    Ackermann, Benjamin
    Ecker, Swantje
    Jaekel, Oliver
    Martisikova, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3737 - 3747
  • [3] Indirect flat-panel detector with avalanche gain
    Zhao, W
    Hunt, DC
    Tanioka, K
    Rowlands, JA
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 150 - 161
  • [4] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [5] Development and characterization of a flat-panel detector-based microtomography system
    Lee, SC
    Kim, HK
    Chun, IK
    Cho, MH
    Cho, MH
    Lee, SY
    [J]. ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 245 - 251
  • [6] Imaging and Dosimetric Study on Direct Flat-Panel Detector-Based Digital Mammography System
    Sharma, Reena
    Sharma, S. D.
    Sarkar, P. S.
    Datta, D.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 255 - 263
  • [7] Portal imaging with flat-panel detector and CCD camera
    Roehrig, H
    Tang, CK
    Cheng, CW
    Dallas, WJ
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 323 - 333
  • [8] Optimizing Parameters for Flat-Panel Detector Digital Tomosynthesis
    Machida, Haruhiko
    Yuhara, Toshiyuki
    Mori, Takako
    Ueno, Eiko
    Moribe, Yoshio
    Sabol, John M.
    [J]. RADIOGRAPHICS, 2010, 30 (02) : 549 - 562
  • [9] Temporal-spatial characteristic evaluation in a dynamic flat-panel detector system
    Kawashima, H.
    Tanaka, R.
    Matsubara, K.
    Ichikawa, K.
    Sakuta, K.
    Minami, S.
    Hayashi, N.
    Sanada, S.
    Kawamura, M.
    Yamamoto, T.
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [10] Challenges in Evaluating Flat-Panel Detector Fluoroscopy Systems
    Mahesh, Mahadevappa
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (03) : 223 - 224