Experimental verification of ion range calculation in a treatment planning system using a flat-panel detector

被引:9
|
作者
Telsemeyer, Julia [1 ,2 ]
Ackermann, Benjamin [3 ]
Ecker, Swantje [3 ]
Jaekel, Oliver [1 ,2 ,3 ]
Martisikova, Maria [1 ,2 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Heidelberg Hosp, Dept RadioOncol & Radiat Therapy, D-69120 Heidelberg, Germany
[3] Heidelberg Ion Beam Therapy Ctr HIT, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 14期
关键词
radiotherapy; carbon ions; ion radiography; semiconductor detector; PROTON; RADIOTHERAPY; RADIOGRAPHY;
D O I
10.1088/0031-9155/59/14/3737
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heavy ion-beam therapy is a highly precise radiation therapy exploiting the characteristic interaction of ions with matter. The steep dose gradient of the Bragg curve allows the irradiation of targets with high-dose and a narrow dose penumbra around the target, in contrast to photon irradiation. This, however, makes heavy ion-beam therapy very sensitive to minor changes in the range calculation of the treatment planning system, as it has a direct influence on the outcome of the treatment. Our previous study has shown that ion radiography with an amorphous silicon flat-panel detector allows the measurement of the water equivalent thickness (WET) of an imaging object with good accuracy and high spatial resolution. In this study, the developed imaging technique is used to measure the WET distribution of a patient-like phantom, and these results are compared to the WET calculation of the treatment planning system. To do so, a measured two-dimensional map of the WET of an anthropomorphic phantom was compared to WET distributions based on x-ray computed tomography images as used in the treatment planning system. It was found that the WET maps agree well in the overall shape and two-dimensional distribution of WET values. Quantitatively, the ratio of the two-dimensional WET maps shows a mean of 1.004 with a standard deviation of 0.022. Differences were found to be concentrated at high WET gradients. This could be explained by the Bragg-peak degradation, which is measured in detail by ion radiography with the flat-panel detector, but is not taken into account in the treatment planning system. Excluding pixels exhibiting significant Bragg-peak degradation, the mean value of the ratio was found to be 1.000 with a standard deviation of 0.012. Employment of the amorphous silicon flat-panel detector for WET measurements allows us to detect uncertainties of the WET determination in the treatment planning process. This makes the investigated technique a very helpful tool to study the WET determination of critical and complex phantom cases.
引用
收藏
页码:3737 / 3747
页数:11
相关论文
共 50 条
  • [1] Experimental in vitro study to evaluate a flat-panel detector system
    Meier, S
    Mildenberger, P
    Oberholzer, K
    Krummenauer, F
    Thelen, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (06): : 875 - 879
  • [2] Geometric Calibration Based on Matrix Calculation for CBCT System with a Flat-panel Detector
    Xu, Xiaofei
    Zhang, Li
    Wu, Dufan
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [4] A testing system of DR based on the Flat-panel detector
    Liang, LH
    Guo, WM
    [J]. ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1915 - 1918
  • [5] Characterization of a flat-panel detector for ion beam spot measurements
    Martisikova, Maria
    Hartmann, Bernadette
    Hesse, Bernd M.
    Brons, Stephan
    Ackermann, Benjamin
    Jaekel, Oliver
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (02): : 485 - 497
  • [6] Fiducial-Based Respiratory Tracking Verification Using A HighResolution Portable Flat-Panel Detector
    Gersh, J.
    Fulkerson, R.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [7] Quantitative carbon ion beam radiography and tomography with a flat-panel detector
    Telsemeyer, Julia
    Jaeakel, Oliver
    Martisikova, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (23): : 7957 - 7971
  • [8] Detection of Pulmonary Embolism Using a Novel Dynamic Flat-Panel Detector System in Monkeys
    Miyatake, Hidemitsu
    Tabata, Takahisa
    Tsujita, Yasuyuki
    Fujino, Kazunori
    Tanaka, Rie
    Eguchi, Yutaka
    [J]. CIRCULATION JOURNAL, 2021, 85 (04) : 361 - 368
  • [9] Experimental evaluation of low-resolution CT regulated tomosynthesis using a flat-panel detector
    Zeng, Kai
    Yu, Hengyong
    Grasruck, Michael
    Schmidt, Bernhard
    Wang, Ge
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [10] Investigations of a flat-panel detector for quality assurance measurements in ion beam therapy
    Hartmann, Bernadette
    Telsemeyer, Julia
    Huber, Lucas
    Ackermann, Benjamin
    Jaekel, Oliver
    Martisikova, Maria
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (01): : 51 - 68