High resolution flat-panel X-ray detector for digital radiography

被引:0
|
作者
Park, JK [1 ]
Kang, SS [1 ]
Cha, BY [1 ]
Kim, JY [1 ]
Kim, SY [1 ]
Choi, HK [1 ]
Nam, SH [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Radiat Image Lab, Kimhae, South Korea
关键词
D O I
10.1109/HEALTH.2005.1500481
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
These In this paper, the evaluation of a selenium-based flat-panel digital X-ray detector is described. The prototype detector has a pixel pitch of 139 mu m and a total active imaging area of 14 inches x 8.5 inches, making up a total of 3.9 million pixels. Several quantitative parameters have been devised that correlate with the abilities of imaging devices to perform clinical tasks. The concepts of MTF, NPS, and DQE have been well described and are very useful descriptors of resolution, noise, and signal-to-noise ratio transfer ability. Such parameters (sensitivity, leakage current, MTF, NPS, DQE) were examined to evaluate the performance of this system. The sensitivity of 4.82 nC/mR/cm(2) was measured at 10 V/mu m, while leakage current was measured at 270 pA/cm(2). The measured MTF at 2 lp/mm was 40%, and the DQE at 1.5 lp/mm was 16%.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 50 条
  • [1] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Kim, JY
    Park, JK
    Choi, JY
    Cha, BY
    Kang, SS
    An, SH
    Nam, SH
    Choi, HK
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4048 - 4052
  • [2] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    [J]. RADIOLOGY, 2001, 221 : 158 - 158
  • [3] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    [J]. NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [4] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [5] Physical Characteristics of a New Flat-Panel Digital X-Ray Detector
    Cho, H.
    Kim, H.
    Park, H.
    Lee, C.
    Yu, A.
    Kim, D.
    Lee, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Imaging characteristics of flat-panel direct X-ray detector with small size pixel elegy for digital radiography
    Wang, Y
    Chen, Y
    [J]. RADIOLOGY, 2002, 225 : 500 - 500
  • [7] Digital radiography system with a full-size, flat-panel X-ray detector: Evaluation of imaging performance
    Neitzel, U
    Maack, I
    Rindt, K
    Spiess, K
    [J]. RADIOLOGY, 1998, 209P : 161 - 161
  • [8] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696
  • [9] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Svenja P. Hennigs
    Marietta Garmer
    Horst J. Jaeger
    Reinhard Classen
    Andreas Jacobs
    Hans M. Gissler
    Andreas Christmann
    Klaus Mathias
    [J]. European Radiology, 2001, 11 : 1688 - 1696
  • [10] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266