Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system

被引:59
|
作者
Spahn, M
Strotzer, M
Völk, M
Böhm, S
Geiger, B
Hahm, G
Feuerbach, S
机构
[1] Siemens AG, Med Engn Angio Fluoro & Rad Syst Dev, D-91301 Forchheim, Germany
[2] Univ Hosp Regensburg, Dept Diagnost Radiol, Regensburg, Germany
关键词
digital radiography; flat-panel detector; amorphous silicon; detective quantum efficiency;
D O I
10.1097/00004424-200004000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO investigate the image quality of a digital radiography system with an amorphous-silicon, large-area, digital flat-panel detector. METHODS. A flat-panel detector based on a matrix of amorphous silicon was integrated into a projection radiography system, The scintillator consisted of a layer of structured cesium iodide, The active matrix size of 3000(2) pixels together with a pixel size of 143 mu m provided a large image area of 43 x 43 cm(2). Basic image quality parameters such as detective quantum efficiency (DQE) and modulation transfer function (MTF) were measured and compared with those obtained with conventional systems, RESULTS. The measurement of DQE yielded a high value of 70% at zero spatial frequency. At a system dose equivalent to 400 speed, the DQE of the digital system was a factor of two larger than the DQE of a storage phosphor or screen-him system within the entire spatial frequency range between zero and the Nyquist limit of 3.5 Line pairs per millimeter, The flat-panel detector furthermore has an MTF that is superior to that in regular screen-film systems and also provides a substantially larger dynamic range. CONCLUSIONS. This new technology demonstrates its potential to provide equal or superior image quality to conventional screen-him systems and to reduce patient exposure to radiation dose. The advantages of digital radiography systems, based on a hat-panel detector as an instant image display, facilitation of work flow in the radiology department, and digital networking and archiving, are well in sight.
引用
收藏
页码:260 / 266
页数:7
相关论文
共 50 条
  • [1] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696
  • [2] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Svenja P. Hennigs
    Marietta Garmer
    Horst J. Jaeger
    Reinhard Classen
    Andreas Jacobs
    Hans M. Gissler
    Andreas Christmann
    Klaus Mathias
    [J]. European Radiology, 2001, 11 : 1688 - 1696
  • [3] Digital radiography with large-area flat-panel detectors
    E. Kotter
    M. Langer
    [J]. European Radiology, 2002, 12 : 2562 - 2570
  • [4] Digital radiography with large-area flat-panel detectors
    Kotter, E
    Langer, M
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (10) : 2562 - 2570
  • [5] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    [J]. Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [6] A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER
    ANTONUK, LE
    YORKSTON, J
    HUANG, WD
    SIEWERDSEN, JH
    BOUDRY, JM
    ELMOHRI, Y
    MARX, MV
    [J]. RADIOGRAPHICS, 1995, 15 (04) : 993 - 1000
  • [7] Finding an improved amorphous-silicon x-ray flat-panel detector configuration for the in-line geometry
    Fast, M. F.
    Teymurazyan, A.
    Pang, G.
    Oelfke, U.
    Rowlands, J. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2305 - 2324
  • [8] Evaluation of a large-area amorphous-silicon X-ray imager
    Jensen, T
    Gray, JN
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 20A AND 20B, 2001, 557 : 1860 - 1867
  • [9] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    [J]. RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [10] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2003, 226 (01) : 221 - 230